ak 110 digital coal troal help

Re: ak 110 digital coal troal help

PostBy: davidmcbeth3 On: Mon Apr 13, 2015 5:41 am

Brandon and Taylor wrote:Posted pictures on new form on coal boilers / coal furnaces


http://nepacrossroads.com/post499176.html#p499176

I think here?
davidmcbeth3
 
Coal Size/Type: nut/pea/anthra
Stove/Furnace Make: Hitzer
Stove/Furnace Model: 503

Re: ak 110 digital coal troal help

PostBy: Brandon and Taylor On: Mon Apr 13, 2015 9:27 am

Im not sure I thought maybe the coal trol
Brandon and Taylor
 
Hot Air Coal Stoker Stove: Reading

Re: ak 110 digital coal troal help

PostBy: Flyer5 On: Mon Apr 13, 2015 1:10 pm

Brandon and Taylor wrote:Does it matter if I don't have a high limit switch?



You should have a L4064B Combination fan limit. It works differently on our furnace. If the Furnace plenum gets to the high limit temperature it disables the combustion fan and feed motor and sets the convection fan to high bypassing the coal trol. The other function it performs is the middle and lower switch control whether or not the fan is allowed to run based on the plenum temp. The coaltrol still controls the convection fan and speed but the fan is disabled till the plenum temp reaches what ever the middle pin is set for. Then it will again become disabled if the temp drops below the lower pin setting. All furnaces had the high limit. When did you buy it and where. You can PM me this info if you like.
Flyer5
 
Stoker Coal Boiler: Leisure Line WL110
Hot Air Coal Stoker Stove: Leisure Line Pioneer

Re: ak 110 digital coal troal help

PostBy: pvolcko On: Sat May 16, 2015 3:21 pm

Make sure your stove is cleaned out of fly ash. A lot of times toward the end of the heating season there is a lot of fly ash built up on the inside the of stoves, resulting in poor heat transfer.
pvolcko