PostBy: Brandon and Taylor On: Fri Apr 10, 2015 11:12 am

I just got my ak 110 fired up yesterday and its about 40 degrees out and I cant get too 70 degrees in the house the air doesn't seem hot coming out of the registers and the blower always seem too run not sure if I have something messed up with the coal troal ?
Brandon and Taylor
 
Hot Air Coal Stoker Stove: Reading

Re: ak 110 digital coal troal help

PostBy: Rob R. On: Fri Apr 10, 2015 11:50 am

What settings are you currently using?
Rob R.
 
Stoker Coal Boiler: EFM DF520
Hand Fed Coal Stove: Hitzer 50-93
Coal Size/Type: Lehigh Rice
Other Heating: Dad's 1953 EFM Highboy

Re: ak 110 digital coal troal help

PostBy: Brandon and Taylor On: Fri Apr 10, 2015 11:57 am

Max 45
min 6
Fsa 0
Cft0
fr 99
d 70
n 65
Brandon and Taylor
 
Hot Air Coal Stoker Stove: Reading

Re: ak 110 digital coal troal help

PostBy: 2001Sierra On: Fri Apr 10, 2015 12:31 pm

FR is 99 so you are feeding maximum coal, how does the fire look?
2001Sierra
 
Hot Air Coal Stoker Stove: Keystoker 90 Chimney vent
Coal Size/Type: Rice
Other Heating: Buderus Oil Boiler 3115-34
Stove/Furnace Model: Keystoker 90 Chimney Vent

Re: ak 110 digital coal troal help

PostBy: Brandon and Taylor On: Fri Apr 10, 2015 12:33 pm

About 1 inch of ash at end of grate
Brandon and Taylor
 
Hot Air Coal Stoker Stove: Reading

Re: ak 110 digital coal troal help

PostBy: 2001Sierra On: Fri Apr 10, 2015 1:21 pm

Your fire is perfect then. The heat problem has got to be downstream of the fire. Can you help us see your ducting?
2001Sierra
 
Hot Air Coal Stoker Stove: Keystoker 90 Chimney vent
Coal Size/Type: Rice
Other Heating: Buderus Oil Boiler 3115-34
Stove/Furnace Model: Keystoker 90 Chimney Vent

Re: ak 110 digital coal troal help

PostBy: Brandon and Taylor On: Fri Apr 10, 2015 1:47 pm

At work now I will post pictures in the morning thanks
Brandon and Taylor
 
Hot Air Coal Stoker Stove: Reading

Re: ak 110 digital coal troal help

PostBy: Flyer5 On: Fri Apr 10, 2015 5:09 pm

Is your combustion fan inlet open all the way?
\
Flyer5
 
Stoker Coal Boiler: Leisure Line WL110
Hot Air Coal Stoker Stove: Leisure Line Pioneer

Re: ak 110 digital coal troal help

PostBy: Brandon and Taylor On: Fri Apr 10, 2015 6:04 pm

Im not sure how do I check that?
Brandon and Taylor
 
Hot Air Coal Stoker Stove: Reading

Re: ak 110 digital coal troal help

PostBy: 2001Sierra On: Fri Apr 10, 2015 10:43 pm

If you have 1 inch of ash at a feed rate of 99 your combustion air should be just fine.
2001Sierra
 
Hot Air Coal Stoker Stove: Keystoker 90 Chimney vent
Coal Size/Type: Rice
Other Heating: Buderus Oil Boiler 3115-34
Stove/Furnace Model: Keystoker 90 Chimney Vent

Re: ak 110 digital coal troal help

PostBy: Flyer5 On: Fri Apr 10, 2015 11:28 pm

Brandon and Taylor wrote:Im not sure how do I check that?


There is a metal plate on the inlet of the combustion blower. Make sure you could see all of the fan opening. None covered by the open plate. If it is covering the inlet a you will be able to bring the Max up even more with a FR of 99. I have seen the 110s w a FR of 48-50 max. When you see a 99 FR you want to adjust the max so you have hot coals right to the edge of the grate but no red coals falling off. I usually set the Max to the point red coal is just falling off the grate then back off by 2. It is important that the FR is 99.
Flyer5
 
Stoker Coal Boiler: Leisure Line WL110
Hot Air Coal Stoker Stove: Leisure Line Pioneer

Re: ak 110 digital coal troal help

PostBy: Brandon and Taylor On: Sat Apr 11, 2015 11:51 pm

Does it matter if I don't have a high limit switch?
Brandon and Taylor
 
Hot Air Coal Stoker Stove: Reading

Re: ak 110 digital coal troal help

PostBy: SWPaDon On: Sat Apr 11, 2015 11:59 pm

Others have asked for pictures of your ducting, can you post them?
SWPaDon
 
Hand Fed Coal Furnace: Clayton 1600M
Coal Size/Type: Bituminous
Other Heating: Oil furnace

Re: ak 110 digital coal troal help

PostBy: Brandon and Taylor On: Sun Apr 12, 2015 9:50 pm

Posted pictures on new form on coal boilers / coal furnaces
Brandon and Taylor
 
Hot Air Coal Stoker Stove: Reading

Re: ak 110 digital coal troal help

PostBy: Rob R. On: Mon Apr 13, 2015 4:43 am

Brandon and Taylor wrote:Does it matter if I don't have a high limit switch?


So what makes the blower cycle on and off?
Rob R.
 
Stoker Coal Boiler: EFM DF520
Hand Fed Coal Stove: Hitzer 50-93
Coal Size/Type: Lehigh Rice
Other Heating: Dad's 1953 EFM Highboy