Reading Question

Post Reply
 
User avatar
bowersox1
Member
Posts: 36
Joined: Sat. Oct. 18, 2014 1:35 am
Location: Lewisburg, Pa
Hot Air Coal Stoker Stove: Reading Allegney Pre 2010 model
Coal Size/Type: Rice

Post by bowersox1 » Tue. Aug. 25, 2015 4:33 pm

I was thinking and not sure so i'll ask the experts. Mt Reading Allegheny originally had the tri-burner set up. I upgraded it to the separate combustion blower package from Reading. The original tri-burner set up has a duct work build into the bottom side of the gear motor housing to direct the combustion air in under the grates. With the new set up this duct is gone. The upgrade combustion blower is 45cfm. Should I cut the opening bigger where the combustion air enters under the grate? Here is a picture of the opening.
air.jpg
.JPG | 75.2KB | air.jpg

 
User avatar
Stoker6268
Member
Posts: 605
Joined: Mon. Feb. 09, 2009 4:49 pm
Location: Grafton NH
Hand Fed Coal Stove: Hitzer 50-93
Coal Size/Type: Pea

Post by Stoker6268 » Tue. Aug. 25, 2015 5:17 pm

The new motor bolts on the back of the motor tray.
If I understand your post,cutting that opening is not an option.
Thats the steel back of stove.
You may have to cut the back of the motor housing a bit.
(Not sure if reading supplies new motor housing/tray) Yours is removed in your pic.
If you have the blower mounted, the air will get in there.
No need for the little channel that the original had.

 
franco b
Site Moderator
Posts: 11417
Joined: Wed. Nov. 05, 2008 5:11 pm
Location: Kent CT
Hand Fed Coal Stove: V ermont Castings 2310, Franco Belge 262
Baseburners & Antiques: Glenwood Modern Oak 114
Coal Size/Type: nut and pea

Post by franco b » Tue. Aug. 25, 2015 6:12 pm

The quality of the fire is the only way to judge.


 
User avatar
bowersox1
Member
Posts: 36
Joined: Sat. Oct. 18, 2014 1:35 am
Location: Lewisburg, Pa
Hot Air Coal Stoker Stove: Reading Allegney Pre 2010 model
Coal Size/Type: Rice

Post by bowersox1 » Tue. Aug. 25, 2015 6:42 pm

I already had the combustion blower. I got it from reading and it came with the Fasco B30 blower and the "pan" to slide under the gear motor. Had to get a new gear motor "pan" cause of the duct work on the underside of the old tri-burner set up. I was just wondering if I should make the opening larger due to the fact that the new combustion blower has more CFM so there fore I would want less restrictions for the air to enter under the grates.

 
User avatar
Stoker6268
Member
Posts: 605
Joined: Mon. Feb. 09, 2009 4:49 pm
Location: Grafton NH
Hand Fed Coal Stove: Hitzer 50-93
Coal Size/Type: Pea

Post by Stoker6268 » Tue. Aug. 25, 2015 7:08 pm

I think youd need a torch to cut that.
It will blow through the hole. Where else can it go.
A little may leak from the tray, but not enough to make a difference.
Not sure if you used with new combustion blower yet, but my bet is you will be looking to lessen the air flow, not increase it.

 
User avatar
Doby
Member
Posts: 477
Joined: Tue. Dec. 02, 2014 9:57 pm
Location: Elysburg PA
Hot Air Coal Stoker Stove: Alaska Kast console and Alaska Channing III
Coal Size/Type: Rice
Other Heating: oil but not much

Post by Doby » Tue. Aug. 25, 2015 7:59 pm

Stoker6268 wrote:I think youd need a torch to cut that.
It will blow through the hole. Where else can it go.
A little may leak from the tray, but not enough to make a difference.
Not sure if you used with new combustion blower yet, but my bet is you will be looking to lessen the air flow, not increase it.
I agree if you notice the coal wants to clinker more the you may have to cut air back abit