Chimney Sizing

Post Reply
 
User avatar
Djcoak6071
Member
Posts: 241
Joined: Sun. Oct. 11, 2015 6:16 am
Location: Youngstown OH Area
Hand Fed Coal Furnace: Yukon - Husky
Coal Size/Type: Anthracite
Other Heating: Oil/Wood

Post by Djcoak6071 » Tue. Oct. 20, 2015 9:36 pm

So I recently bought a Yukon husky wood oil coal furnace. Due to not being able to add a chimney and the oil burner dying I felt this was the best option. The furnace is rated at 112,000 btus. I noticed today that the chimney that this would connect to is smaller than the one for the fireplace. I did add a 6" SS liner to the fireplace chimney due to tile issues.

The one my new furnace Connects to is 6 3/4 x 11. I was going to add a liner but I believe it needs an 8" which obviously won't fit. So am I in trouble here?

 
lzaharis
Member
Posts: 2365
Joined: Sun. Mar. 25, 2007 8:41 pm
Location: Ithaca, New York
Stoker Coal Boiler: Keystoker KAA-4-1 dual fuel boiler
Hand Fed Coal Boiler: former switzer CWW100-sold
Coal Size/Type: rice
Other Heating: kerosene for dual fuel Keystoker/unused

Post by lzaharis » Wed. Oct. 21, 2015 8:52 am

Every bit of this is going to depend on your
chimneys height as the stack height is going to
create the pressure gradient to allow proper
combustion in your firebox.

The only way to really check is use a good
draft guage when you are hand firing it and
making sure you follow Yukons recommendations
for installation as you may end up needing a chimney
top draft inducer.

You may just need a chimney pot/chimney extension
that screws to the chimney collar/raincap.

I have a chimney extension from Rockford Chimney
Supply and I was very happey with the quality of
the work done to manufacture it. It also came to
the house undamaged from shipping it so the
packaging of it prior to shipment was done well
with double boxing it.

The chimney extension comes with a mounting
base that is screwed into place using tap cons and
the extension is bolted into place using a hinge to
allow for chimney cleaning.

 
User avatar
Djcoak6071
Member
Posts: 241
Joined: Sun. Oct. 11, 2015 6:16 am
Location: Youngstown OH Area
Hand Fed Coal Furnace: Yukon - Husky
Coal Size/Type: Anthracite
Other Heating: Oil/Wood

Post by Djcoak6071 » Wed. Oct. 21, 2015 4:14 pm

Furnace is in the basement of my ranch. I would guess the chimney is at least 26 - 28 foot as it take 20 foot of rod to clean the fireplace flue on the first floor. So really I won't know till I hook it up.
Last edited by Djcoak6071 on Wed. Oct. 21, 2015 4:17 pm, edited 1 time in total.

 
User avatar
Djcoak6071
Member
Posts: 241
Joined: Sun. Oct. 11, 2015 6:16 am
Location: Youngstown OH Area
Hand Fed Coal Furnace: Yukon - Husky
Coal Size/Type: Anthracite
Other Heating: Oil/Wood

Post by Djcoak6071 » Wed. Oct. 21, 2015 4:16 pm

Is a draft inducer really 2 grand????? If so I'll sell the furnace. Screw that.


 
franco b
Site Moderator
Posts: 11416
Joined: Wed. Nov. 05, 2008 5:11 pm
Location: Kent CT
Hand Fed Coal Stove: V ermont Castings 2310, Franco Belge 262
Baseburners & Antiques: Glenwood Modern Oak 114
Coal Size/Type: nut and pea

Post by franco b » Wed. Oct. 21, 2015 4:35 pm

Draft inducers are not $2000 and you should not need one.

A chimney liner is something to be avoided if possible, so look real hard at the present liner to see if it might do or can be repaired.

Your stove has a large flue outlet because it is rated for wood. Wood has a large rush of gas and smoke when first heated so needs that capacity. Coal does not do that and 6 inch should handle 112,000 BTU easily and you most likely will never burn at that rate anyway.

 
User avatar
Djcoak6071
Member
Posts: 241
Joined: Sun. Oct. 11, 2015 6:16 am
Location: Youngstown OH Area
Hand Fed Coal Furnace: Yukon - Husky
Coal Size/Type: Anthracite
Other Heating: Oil/Wood

Post by Djcoak6071 » Wed. Oct. 21, 2015 4:54 pm

Whew. Good points although I do plan to burn so wood also or at least have the option.

 
franco b
Site Moderator
Posts: 11416
Joined: Wed. Nov. 05, 2008 5:11 pm
Location: Kent CT
Hand Fed Coal Stove: V ermont Castings 2310, Franco Belge 262
Baseburners & Antiques: Glenwood Modern Oak 114
Coal Size/Type: nut and pea

Post by franco b » Wed. Oct. 21, 2015 5:05 pm

Djcoak6071 wrote:Whew. Good points although I do plan to burn so wood also or at least have the option.
Just feel your way with wood and if it backs up just load smaller loads at a time or do it in two steps spaced 30 min. apart. Avoid long slow burns that create creosote. The Yukon might be EPA approved which means cleaner burns with wood.

 
User avatar
Djcoak6071
Member
Posts: 241
Joined: Sun. Oct. 11, 2015 6:16 am
Location: Youngstown OH Area
Hand Fed Coal Furnace: Yukon - Husky
Coal Size/Type: Anthracite
Other Heating: Oil/Wood

Post by Djcoak6071 » Wed. Oct. 21, 2015 5:39 pm

Ironically my wood burning fireplace is 6" and the firebox is about the same size as the husky.


 
coalder
Member
Posts: 1493
Joined: Mon. Dec. 16, 2013 1:48 pm
Location: somewhere high in the catskill mountains
Hand Fed Coal Boiler: harman sf 160
Coal Size/Type: Nut
Other Heating: wood parlor stove

Post by coalder » Wed. Oct. 21, 2015 5:55 pm

Shouldn't need anything. Check draft by lighting a piece of newspaper in the cleanout. Ifn it sounds like a jet engine , & sucks up the paper you are good to go. Shouldn't need anything else. With a chimney that tall you will be fine.
Jim

 
User avatar
Djcoak6071
Member
Posts: 241
Joined: Sun. Oct. 11, 2015 6:16 am
Location: Youngstown OH Area
Hand Fed Coal Furnace: Yukon - Husky
Coal Size/Type: Anthracite
Other Heating: Oil/Wood

Post by Djcoak6071 » Wed. Oct. 21, 2015 5:57 pm

Thanks guys. Nothing worse than spending the dollars then thinking you lost out

 
User avatar
Djcoak6071
Member
Posts: 241
Joined: Sun. Oct. 11, 2015 6:16 am
Location: Youngstown OH Area
Hand Fed Coal Furnace: Yukon - Husky
Coal Size/Type: Anthracite
Other Heating: Oil/Wood

Post by Djcoak6071 » Thu. Oct. 22, 2015 6:30 am

So tile should also be able to handle the combination of burning wood and coal?

 
User avatar
freetown fred
Member
Posts: 30293
Joined: Thu. Dec. 31, 2009 12:33 pm
Location: Freetown,NY 13803
Hand Fed Coal Stove: HITZER 50-93
Coal Size/Type: BLASCHAK Nut

Post by freetown fred » Thu. Oct. 22, 2015 7:12 am

Always has, always will. :)