762 total lbs. of coal burned
Estimated 140 lbs. to heat DHW (assumption : 4.5 lbs. per day)
Estimated 622 lbs. to heat home
395 local HDD's (computed via the nearest Weather Underground back-yard weather station, ~1.5 miles from my house)
~1.57 lbs. per HDD
October 2015, the S130 Coal Gun's Tale of the Tape
- StokerDon
- Site Moderator
- Posts: 7486
- Joined: Mon. Nov. 11, 2013 11:17 am
- Location: PA, Southern York County!
- Stoker Coal Boiler: Gentleman Janitor GJ-5, Van Wert VA-600, Axeman Anderson130 X3.
- Hand Fed Coal Furnace: Harman SF3500 reduced down to 3 grates connected to its own plenum
- Coal Size/Type: Rice, Chestnut and whatever will fit through the door on the Harman
- Other Heating: Noth'in but COAL! Well, Maybe a little tiny bit of wood
I wish I was where you are on coal consumption Larry. I'm at 1500 pounds on the nose from Sept 30 to Oct 30. 50 pounds per day. Temps in the mid to upper 60's most days. Only 3 or 4 nights below freezing.
-Don
-Don
- lsayre
- Member
- Posts: 21781
- Joined: Wed. Nov. 23, 2005 9:17 pm
- Location: Ohio
- Stoker Coal Boiler: AHS S130 Coal Gun
- Coal Size/Type: Lehigh Anthracite Pea
- Other Heating: Resistance Boiler (13.5 KW), ComfortMax 75
I'm not heating a garage like you are.StokerDon wrote:I wish I was where you are on coal consumption Larry. I'm at 1500 pounds on the nose from Sept 30 to Oct 30. 50 pounds per day. Temps in the mid to upper 60's most days. Only 3 or 4 nights below freezing.
-Don
- hotblast1357
- Member
- Posts: 5657
- Joined: Mon. Mar. 10, 2014 10:06 pm
- Location: Peasleeville NY
- Stoker Coal Boiler: 1984 Eshland S260 coal gun
- Coal Size/Type: Lehigh anthracite pea
- Other Heating: air source heat pump, oil furnace
hmm I must be doing alright then, 948 pounds for the month of october. thats house, dhw, and some heat calls in the garage. thats 30.5 lbs per day. I think ill take it for a hand fed.
- lsayre
- Member
- Posts: 21781
- Joined: Wed. Nov. 23, 2005 9:17 pm
- Location: Ohio
- Stoker Coal Boiler: AHS S130 Coal Gun
- Coal Size/Type: Lehigh Anthracite Pea
- Other Heating: Resistance Boiler (13.5 KW), ComfortMax 75
I should have stated that my garage is on its own T-Stat and zone loop, but to date it has not gotten cold enough for a heat call to have occurred in my attached garage that is effectively half of the homes walk-out basement.
Hotblast1357, the region around Plattsburgh, NY generally has about 22% more HDD's that we get in the vicinity of Wadsworth, OH, so (all else being equal) you should burn about 22% more coal per month than I do. Sounds like you are doing just fine.
Hotblast1357, the region around Plattsburgh, NY generally has about 22% more HDD's that we get in the vicinity of Wadsworth, OH, so (all else being equal) you should burn about 22% more coal per month than I do. Sounds like you are doing just fine.