Draft Induction Fan

 
raye321
New Member
Posts: 16
Joined: Wed. Feb. 20, 2013 2:16 pm

Post by raye321 » Tue. Dec. 01, 2015 12:12 pm

I'm having trouble with my coal furnace smoking when I first start a fire and also when I add coal. I have it in my garage so I have to start it every time I use it. Is there a draft fan that will work on the flue pipe going from the furnace to the chimney?


 
titleist1
Member
Posts: 5226
Joined: Wed. Nov. 14, 2007 4:06 pm

Post by titleist1 » Tue. Dec. 01, 2015 1:05 pm

Is this just a problem on start up until the chimney gets heated up or is it an issue whenever you add coal no matter how long the stove has been burning?

 
raye321
New Member
Posts: 16
Joined: Wed. Feb. 20, 2013 2:16 pm

Post by raye321 » Tue. Dec. 01, 2015 2:02 pm

Mostly on start up. After the coal is glowing hot it does do it a little bit. I think if I could install a draft fan should solve it. It's an old furnace I use in my garage.

 
User avatar
Lightning
Site Moderator
Posts: 14658
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Tue. Dec. 01, 2015 2:30 pm

Yes, there are flue pipe draft inducers. I used to use one. As a matter of fact I still have it. I don't use it anymore. You could try preheating the pipe with a hair dryer or heat gun for a few minutes just before lighting your fire. Just stick it in the pipe and blast it up thru there for 5 minutes, get everything warm so it can start drafting.

 
raye321
New Member
Posts: 16
Joined: Wed. Feb. 20, 2013 2:16 pm

Post by raye321 » Tue. Dec. 01, 2015 2:55 pm

What kind did you use? I need one that will take the heat.

 
raye321
New Member
Posts: 16
Joined: Wed. Feb. 20, 2013 2:16 pm

Post by raye321 » Tue. Dec. 01, 2015 3:01 pm

I am having trouble with my coal furnace smoking on start up and also when adding coal to the fire. The furnace is used in my garage so I have to start it every time I use it. Is there a draft fan that will work on th flue pipe going from the furnace to the chimney?

 
User avatar
Lightning
Site Moderator
Posts: 14658
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Tue. Dec. 01, 2015 3:13 pm



 
raye321
New Member
Posts: 16
Joined: Wed. Feb. 20, 2013 2:16 pm

Post by raye321 » Tue. Dec. 01, 2015 4:07 pm

Yicks, $155. Do you think the Tjeinlund D-3 would work? I saw one for $108 The DB-2 for $70.

 
User avatar
Lightning
Site Moderator
Posts: 14658
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Tue. Dec. 01, 2015 4:08 pm

If yer interested, I could sell you mine. I don't plan on using it.

 
raye321
New Member
Posts: 16
Joined: Wed. Feb. 20, 2013 2:16 pm

Post by raye321 » Tue. Dec. 01, 2015 4:54 pm

Yes, How much do you want for it?

 
User avatar
Lightning
Site Moderator
Posts: 14658
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Tue. Dec. 01, 2015 5:06 pm

raye321 wrote:Yes, How much do you want for it?
I'll take $40 plus the cost of shipping it. But let me run some power to it and just make sure it runs ok. It's got a little corrosion but should do it's job just fine provided it runs. It's got a variable speed adjustment knob to control the speed. It'll crank if ya make it, the lower setting is plenty. You'll have to cut a hole in the pipe to mount it.

You might wanna try priming your chimney with a hair dryer or heat gun before fiddling with an inducer. Just a suggestion.. :)

 
raye321
New Member
Posts: 16
Joined: Wed. Feb. 20, 2013 2:16 pm

Post by raye321 » Tue. Dec. 01, 2015 5:12 pm

I don't think the hairdyer will work. It's an old furnace I think a draft fan will help alot. Let me know how it runs. If your in 14760 zip code I'm in 15904. Should be maybe $10 if ship by USPS?

 
User avatar
WNY
Member
Posts: 6307
Joined: Mon. Nov. 14, 2005 8:40 am
Location: Cuba, NY
Hot Air Coal Stoker Stove: Keystoker 90K, Leisure Line Hyfire I
Coal Size/Type: Rice
Contact:

Post by WNY » Tue. Dec. 01, 2015 5:13 pm

What is smoking, the pipe? or the stove itself? maybe you need some gaskets on the doors, or seal the pipe up a little better. A lot of the stoves smoke some on startup, but are usually sealed pretty good to prevent it. if you have a baro damper on the pipe, put a piece of aluminum foil or something over the opening until you get the heat going up the chimney.

 
User avatar
Lightning
Site Moderator
Posts: 14658
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Tue. Dec. 01, 2015 5:20 pm

raye321 wrote:I don't think the hairdyer will work. It's an old furnace I think a draft fan will help alot. Let me know how it runs. If your in 14760 zip code I'm in 15904. Should be maybe $10 if ship by USPS?
Should be under $20 for shipping. It's not quite 10 pounds, but probably close to it. Really though, have your kindling ready to light then go in thru the load door and blast a hair dryer directly into the pipe for about 10 minutes. Get the pipe nice and warm, then light your fire. I bet it would do the trick for ya.

 
voodoochylde
Member
Posts: 90
Joined: Wed. Feb. 20, 2013 4:35 pm
Location: Greenbrier, WV
Hot Air Coal Stoker Furnace: Modified Combustioneer 77b w/1000cfm blower
Hand Fed Coal Stove: Locke Warm Morning 818
Hand Fed Coal Furnace: Hitzer 55FA (not currently in operation)

Post by voodoochylde » Tue. Dec. 01, 2015 5:42 pm

Is this a handfed or stoker furnace? If handfed, it's against code and dangerous to install a power vent on it. If the power fails, the natural draft of the chimney may not be enough to evacuate flue gases and could flood the garage with coal gas, which contains carbon monoxide.

If it's a stoker, you can probably use a power vent.


Post Reply

Return to “Coal Bins, Chimneys, CO Detectors & Thermostats”