Hello all from just south of Carrolton

Re: Hello all from just south of Carrolton

PostBy: McGiever On: Sun Dec 13, 2015 8:01 am

CM, I'm a bit north and east of you, in Columbiana County. :)

By your board name and gas/oil reference, do you work with cathodic protection?

I have worked constructing and upgrading some compressor stations and other pipeline related jobs scattered about the country. (my trade is electrical)
McGiever
 
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Coal Size/Type: PEA / ANTHRACITE
Other Heating: Ground Source Heat Pump
Stove/Furnace Make: Hydro Heat /Mega Tek


Re: Hello all from just south of Carrolton

PostBy: CorrosionMan On: Sun Dec 13, 2015 12:34 pm

McGiever wrote:CM, I'm a bit north and east of you, in Columbiana County. :)

By your board name and gas/oil reference, do you work with cathodic protection?

I have worked constructing and upgrading some compressor stations and other pipeline related jobs scattered about the country. (my trade is electrical)


Yes, that is my main function.

I want to speak with you about changing my generator connection to my house. It is setup with a interlock and 100 amp breaker with a l14-30 connector. I want to change to a 50 amp plug. Would this be much of an issue?
CorrosionMan
 
Hand Fed Coal Furnace: Hitzer 82 FA
Coal Size/Type: Reading NUT 40lb plastic bags
Other Heating: Heat Pump

Re: Hello all from just south of Carrolton

PostBy: McGiever On: Sun Dec 13, 2015 7:22 pm

Pictures will make for a better explanation. :)
McGiever
 
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Coal Size/Type: PEA / ANTHRACITE
Other Heating: Ground Source Heat Pump
Stove/Furnace Make: Hydro Heat /Mega Tek

Re: Hello all from just south of Carrolton

PostBy: CorrosionMan On: Fri Dec 25, 2015 1:46 pm

Currently in Florida! Merry Xmas everyone!
Attachments
IMG_20151121_152502408.jpg
(86.59 KiB) Viewed 8 times
View: New PagePopup • Select:BBCode
L14-30 plug
[nepathumb]69864[/nepathumb]
CorrosionMan
 
Hand Fed Coal Furnace: Hitzer 82 FA
Coal Size/Type: Reading NUT 40lb plastic bags
Other Heating: Heat Pump

Re: Hello all from just south of Carrolton

PostBy: McGiever On: Fri Dec 25, 2015 2:56 pm

CorrosionMan wrote:
I want to speak with you about changing my generator connection to my house. It is setup with a interlock and 100 amp breaker with a l14-30 connector. I want to change to a 50 amp plug. Would this be much of an issue?



https://www.platt.com/platt-electric-su ... pid=222157
McGiever
 
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Coal Size/Type: PEA / ANTHRACITE
Other Heating: Ground Source Heat Pump
Stove/Furnace Make: Hydro Heat /Mega Tek

Re: Hello all from just south of Carrolton

PostBy: CorrosionMan On: Fri Dec 25, 2015 3:06 pm

Exactly. If I use/replace the wire to six guage. This will be to code?
CorrosionMan
 
Hand Fed Coal Furnace: Hitzer 82 FA
Coal Size/Type: Reading NUT 40lb plastic bags
Other Heating: Heat Pump

Re: Hello all from just south of Carrolton

PostBy: McGiever On: Fri Dec 25, 2015 3:11 pm

CorrosionMan wrote:Exactly. If I use/replace the wire to six guage. This will be to code?


Yep,

Shop around that's not the best price there. :)
McGiever
 
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Coal Size/Type: PEA / ANTHRACITE
Other Heating: Ground Source Heat Pump
Stove/Furnace Make: Hydro Heat /Mega Tek