Themostat Not Starting Gear Motor

Post Reply
 
Cookingarcher
New Member
Posts: 2
Joined: Tue. Feb. 24, 2015 4:59 pm
Hot Air Coal Stoker Stove: Keystoker
Coal Size/Type: Rice

Post by Cookingarcher » Tue. Jan. 05, 2016 6:30 pm

I have had my keystoker for about a year. Today when calling for heat in never starts the pusher motor.

 
User avatar
WNY
Member
Posts: 6307
Joined: Mon. Nov. 14, 2005 8:40 am
Location: Cuba, NY
Hot Air Coal Stoker Stove: Keystoker 90K, Leisure Line Hyfire I
Coal Size/Type: Rice
Contact:

Post by WNY » Tue. Jan. 05, 2016 6:39 pm

Check the wiring, etc.. take the cover off the box on the stove and make sure the connections are all tight for the thermostat.
Assuming you do the spring cleaning and maintenance on it, clean it good, etc...give us a few more details or post a pic of your setup.

what type of thermostat? If it's digital, you might need new batteries.

turning it up or down you don't here a click on the stove to activate the stoker?

Unplug it and plug it back in, see if it resets, etc....

 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Tue. Jan. 05, 2016 7:23 pm

Cookingarcher wrote:I have had my keystoker for about a year. Today when calling for heat in never starts the pusher motor.
We can guess all day...does the feeder motor get hot to the touch like it is bound up?

Gears can get jambed or bound up and stop motor rotation. Faulty wiring might leave it cold to the touch...which is your's?.:idea:

 
Cookingarcher
New Member
Posts: 2
Joined: Tue. Feb. 24, 2015 4:59 pm
Hot Air Coal Stoker Stove: Keystoker
Coal Size/Type: Rice

Post by Cookingarcher » Tue. Jan. 05, 2016 7:34 pm

I have replaced the battery. Checked all electrical connections. The propeller is running on the gear motor only when the timer is making it run.


 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Tue. Jan. 05, 2016 7:42 pm

Cookingarcher wrote:I have replaced the battery. Checked all electrical connections. The propeller is running on the gear motor only when the timer is making it run.
Okay, t'stat has new battery and motor run happily off timer...now we're making headway. :)

If t'stat truly is closed your controller is ka-put. Try shorting out the TT terminals on the controller with the t'stat wires removed. If that works throw that t'stat away and get another. If it don't work find a new controller part.
Last edited by McGiever on Tue. Jan. 05, 2016 7:44 pm, edited 1 time in total.

 
User avatar
WNY
Member
Posts: 6307
Joined: Mon. Nov. 14, 2005 8:40 am
Location: Cuba, NY
Hot Air Coal Stoker Stove: Keystoker 90K, Leisure Line Hyfire I
Coal Size/Type: Rice
Contact:

Post by WNY » Tue. Jan. 05, 2016 7:43 pm

If it's idling from the timer box and will maintain a fire at idle, then the stoker motor seems to be working.
it could be electrical with the transformer in the box on the back of the stove or thermostat. make sure if you remove the front of the thermostat for changing the batteries, it was put back on and making good contact. sometimes they have to snap back onto the mounting bracket.

 
User avatar
WNY
Member
Posts: 6307
Joined: Mon. Nov. 14, 2005 8:40 am
Location: Cuba, NY
Hot Air Coal Stoker Stove: Keystoker 90K, Leisure Line Hyfire I
Coal Size/Type: Rice
Contact:

Post by WNY » Wed. Jan. 06, 2016 6:36 pm

Any update on your thermostat/motor not working properly?