Hydrostat 3250 Opinions- Will I Save Money? Pro and Cons?

 
lzaharis
Member
Posts: 2379
Joined: Sun. Mar. 25, 2007 8:41 pm
Location: Ithaca, New York
Stoker Coal Boiler: Keystoker KAA-4-1 dual fuel boiler
Hand Fed Coal Boiler: former switzer CWW100-sold
Coal Size/Type: rice
Other Heating: kerosene for dual fuel Keystoker/unused

Post by lzaharis » Sat. Jan. 30, 2016 11:53 am

Hey Rob,

Not that its a big deal my 8124M schematic shows
a line voltage circulator connected to C1 and C2.

 
User avatar
Scottscoaled
Member
Posts: 2812
Joined: Tue. Jan. 08, 2008 9:51 pm
Location: Malta N.Y.
Stoker Coal Boiler: EFM 520, 700, Van Wert 800 GJ 61,53
Baseburners & Antiques: Magic Stewart 16, times 2!
Coal Size/Type: Lots of buck
Other Heating: Slant Fin electric boiler backup

Post by Scottscoaled » Sat. Jan. 30, 2016 12:27 pm

lzaharis wrote:Hey Rob,

Not that its a big deal my 8124M schematic shows
a line voltage circulator connected to C1 and C2.
Leon. Not the same. The 8124m runs the boiler to high limit without a heat call. The TT terminal only runs the circulator. The M model keeps the boiler temp pegged to the high limit setting. Simple control.

 
User avatar
ShawnTRD
Member
Posts: 519
Joined: Tue. Feb. 04, 2014 1:04 am
Location: Spencer, NY
Stoker Coal Boiler: Keystoker KA6 (New in April 2014)
Coal Size/Type: Anthracite Rice
Other Heating: Weil Mclain WGO-2 (Net 75k BTU)

Post by ShawnTRD » Sat. Mar. 26, 2016 3:28 pm

FYI
The L8124A-1114 that came with my KA-6 has been replaced with L7224U-1002. I just installed it last night and so far it's working great.


 
User avatar
CoalisCoolxWarm
Member
Posts: 2323
Joined: Wed. Jan. 19, 2011 11:41 am
Location: Western PA
Stoker Coal Boiler: Keystoker KA-6
Hand Fed Coal Furnace: old Sears rebuilt, bituminous- offline as of winter 2014
Coal Size/Type: Anthracite Buckwheat
Other Heating: Oil Boiler

Post by CoalisCoolxWarm » Sat. Mar. 26, 2016 5:33 pm

ShawnTRD wrote:FYI
The L8124A-1114 that came with my KA-6 has been replaced with L7224U-1002. I just installed it last night and so far it's working great.
Thanks for the info. Good to know there's a decent replacement :)

We are down to about 7-10 days of coal. That puts us at about 2.5 tons for this mild heating season. We estimated up to 6 tons. I figure we'll use another 1/2 ton if we continue to heat until we can't stand it.

I'm not really active on the board right now, but got notice of your reply to my thread and appreciate the courtesy :cheers:

Happy Easter everyone!

 
User avatar
ShawnTRD
Member
Posts: 519
Joined: Tue. Feb. 04, 2014 1:04 am
Location: Spencer, NY
Stoker Coal Boiler: Keystoker KA6 (New in April 2014)
Coal Size/Type: Anthracite Rice
Other Heating: Weil Mclain WGO-2 (Net 75k BTU)

Post by ShawnTRD » Sat. Mar. 26, 2016 5:44 pm