So my house has baseboard heat with radiant flooring in the kitchen, dining room, and two bathrooms. From what I can see the flooring was installed with the Pex just stapled to the floor. I want to redo it with the metal channels going down both sides the the floor joists, and then insulate it before replacing the sheet rock ceiling in the basement. I'm also thinking of maybe just having the whole floor plan done. Anyone have a rough idea what that might cost if I had it professionally done?

1800 Sq ft.
Maybe two zones

 
snuffy
Member
Posts: 533
Joined: Fri. Jan. 25, 2008 11:55 pm
Hand Fed Coal Stove: Harman SF250 & Mark III backup
Other Heating: Oil Hot Water

Post by snuffy » Wed. Feb. 10, 2016 10:18 pm

I had a quote last summer for a ranch home about 1600 SF for pex and insulated bubble wrap but no aluminum channels and it came in about $4.00 to $5.00 per sq ft. That price might have included a four zone manifold and necessary controls. But it should give you an approximate range. I did not get the work done because of cost overruns on other parts of the rehab so that was the first to be axed.

 
User avatar
CoalisCoolxWarm
Member
Posts: 2323
Joined: Wed. Jan. 19, 2011 11:41 am
Location: Western PA
Stoker Coal Boiler: Keystoker KA-6
Hand Fed Coal Furnace: old Sears rebuilt, bituminous- offline as of winter 2014
Coal Size/Type: Anthracite Buckwheat
Other Heating: Oil Boiler

Post by CoalisCoolxWarm » Wed. Feb. 10, 2016 11:58 pm

When I looked into this a while back, the plates were always the expensive part.

Considered making them, saw some cool DIY jigs, but too many other things going on at the time.

But the price of metals is way down right now, so maybe they're more attractively priced now?

Can't help you on an installation price, sorry.


 
User avatar
Sting
Member
Posts: 2983
Joined: Mon. Feb. 25, 2008 4:24 pm
Location: Lower Fox Valley = Wisconsin
Other Heating: OBSO Lennox Pulse "Air Scorcher" burning NG

Post by Sting » Thu. Feb. 11, 2016 7:18 am

unless you don't have a life - or want a poor transfer of heat energy from the pex to the plate

Wait and buy the factory formed plates at the big box store when they come on sale.
Staple them [with the pex enclosed of course] UNDER the floor - not on the floor joist

Your mileage may vary

before pex = I purchased end lots of fin tube Anything I could find sometimes I could get boxes of fin tube that had the ends smashed. I would hang this in the center of the joist bay on blocks or chunks of foam insulation so as to muffle or stop all expansion noise - then enclose the joint bay with foil face sheets = LABOR INTENSIVE at best. The joist bay then became a small inefficient "radiator" - and the floor was warm to bare feet. Usually not enough to replace the traditional radiation - but that flow and energy could be balanced out to play well with the added radiation of the floor.

Kind Regards
Sting

 
User avatar
CoalisCoolxWarm
Member
Posts: 2323
Joined: Wed. Jan. 19, 2011 11:41 am
Location: Western PA
Stoker Coal Boiler: Keystoker KA-6
Hand Fed Coal Furnace: old Sears rebuilt, bituminous- offline as of winter 2014
Coal Size/Type: Anthracite Buckwheat
Other Heating: Oil Boiler

Post by CoalisCoolxWarm » Thu. Feb. 11, 2016 9:52 am

Sting wrote:before pex = I purchased end lots of fin tube Anything I could find sometimes I could get boxes of fin tube that had the ends smashed. I would hang this in the center of the joist bay on blocks or chunks of foam insulation so as to muffle or stop all expansion noise - then enclose the joint bay with foil face sheets = LABOR INTENSIVE at best. The joist bay then became a small inefficient "radiator" - and the floor was warm to bare feet. Usually not enough to replace the traditional radiation - but that flow and energy could be balanced out to play well with the added radiation of the floor.
That's quite interesting... I'm always amazed at people's innovations ;)