Aquastat Wiring for Outfire

Post Reply
 
coalmanjoe
Member
Posts: 27
Joined: Sun. Dec. 21, 2014 8:21 am
Location: Mt. Carmel
Stoker Coal Boiler: EFM 520
Coal Size/Type: Rice

Post by coalmanjoe » Mon. Apr. 04, 2016 2:42 pm

I have a Honeywell 6006A aquastat that I would like to use as an outfire control on my EFM. Although I have piped and wired a few stokers in the past I have never put an outfire control on them. The schematic shows that R B opens and R W closes on temperature increase. Am I correct to assume that I will only be using the R and W terminals???? Also, does it matter which terminal I connect the incoming hot line to?? I understand the need for a bypass switch to restart the boiler. Any help will be greatly appreciated.

 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Mon. Apr. 04, 2016 3:47 pm

You got it! 8-)
And it does not matter which.

Proceed with confidence, my Friend. :)


 
coalmanjoe
Member
Posts: 27
Joined: Sun. Dec. 21, 2014 8:21 am
Location: Mt. Carmel
Stoker Coal Boiler: EFM 520
Coal Size/Type: Rice

Post by coalmanjoe » Mon. Apr. 04, 2016 3:57 pm

Thank you my friend!!!!

Post Reply