I looked a the info on power vent and it says for C. Must terminate at least 4' below, 4' horizontally, or 1' above any door or window.
I would like to put the power vent 5ft directly below a window is that O.K. ? Or does it also have to be 4ft horizontally away from the window?
Thanks for your help
Proper Location of a Power Vent
-
- Member
- Posts: 300
- Joined: Sat. Apr. 19, 2008 1:29 pm
- Location: long Island,NY
- Stoker Coal Boiler: harmanVF3000 Coal/oil option
- Coal Size/Type: Rice
-
- Member
- Posts: 381
- Joined: Mon. Jan. 23, 2006 7:30 pm
- Location: Berwick, pa
- Contact:
Your fine. 4 ft below will work.
Thanks,
Jerry
Thanks,
Jerry