Coal-Trol Gone Wacky With a Hyfire II

Post Reply
 
bernincoal
Member
Posts: 22
Joined: Mon. Nov. 16, 2015 12:53 pm
Location: NEPA
Hot Air Coal Stoker Furnace: Hyfire II
Coal Size/Type: Rice

Post by bernincoal » Sun. Dec. 04, 2016 3:19 pm

I have a Hyfire II. This year, the left coal feeder keeps feeding coal while the right acts 'normal'. The big blower fans are at full speed and don't stop. This never happened before. In past seasons, both feeders fed normally and the blowers went on when needed. Everything is connected correctly. What is the problem?

Thank you

 
User avatar
WNY
Member
Posts: 6307
Joined: Mon. Nov. 14, 2005 8:40 am
Location: Cuba, NY
Hot Air Coal Stoker Stove: Keystoker 90K, Leisure Line Hyfire I
Coal Size/Type: Rice
Contact:

Post by WNY » Sun. Dec. 04, 2016 5:01 pm

Both feeders should be feeding the same.

Did you just plug it and start using it? whats the FEED RATE (FR)? if it's says 99 then both stokers should run a lot and the blowers will be running full. If so, turn your setpoint down below room temp. IT takes time to react, it might take a few hours for it to stabilize again and get back on track.

Almost sounds like you have something wired wrong, check the cabling, check the Thermostat cable too, unplug and plug everything back in. something might be loose or dirty. Have you powered it down, unplug the control box, and replug everything back in, I know you;ll have reset date and time.

 
bernincoal
Member
Posts: 22
Joined: Mon. Nov. 16, 2015 12:53 pm
Location: NEPA
Hot Air Coal Stoker Furnace: Hyfire II
Coal Size/Type: Rice

Post by bernincoal » Sun. Dec. 04, 2016 7:08 pm

I'll start all over again and bring the setpoint below room temp. I'll check all the cabling.

Thank you! :)


 
User avatar
WNY
Member
Posts: 6307
Joined: Mon. Nov. 14, 2005 8:40 am
Location: Cuba, NY
Hot Air Coal Stoker Stove: Keystoker 90K, Leisure Line Hyfire I
Coal Size/Type: Rice
Contact:

Post by WNY » Mon. Dec. 05, 2016 8:47 pm

any luck getting back to normal running?

 
bernincoal
Member
Posts: 22
Joined: Mon. Nov. 16, 2015 12:53 pm
Location: NEPA
Hot Air Coal Stoker Furnace: Hyfire II
Coal Size/Type: Rice

Post by bernincoal » Mon. Dec. 05, 2016 10:29 pm

The right burner is normal but left is not. I haven't checked everything yet but I will.

Thank you for checking in. :)

 
User avatar
Flyer5
Member
Posts: 10376
Joined: Sun. Oct. 21, 2007 4:23 pm
Location: Montrose PA
Stoker Coal Boiler: Leisure Line WL110
Hot Air Coal Stoker Stove: Leisure Line Pioneer
Contact:

Post by Flyer5 » Tue. Dec. 20, 2016 8:46 am

bernincoal wrote:The right burner is normal but left is not. I haven't checked everything yet but I will.

Thank you for checking in. :)
Left an right feeders share the same output. Make sure your fan dampers are open the same. Make sure both feed motors ( RED WIRE TIE) are plugged into the same Y cord.

Post Reply