PostBy: philthy On: Wed. Jan. 18, 2017 9:57 pm

Today I did the combustion fan upgrade to my Alaska out in the garage which is power-vented. In the process I decided to test the fume switch by applying heat to the inside where the flume switch comes thru. Nothing! Upon further inspection the tube was so plugged up with gunk that it wouldn't respond. I got in there with an awl and compressed air and got it cleaned out. After cleaning it worked as it should.

Maybe most are aware and clean regularly but I wasn't and wanted to share with those that may not be. I bought the stove used and installed last winter with a new power vent but never thought to check the operation of the fume switch. :oops:
philthy
 
Hot Air Coal Stoker Stove: Keystoke Koker Lite, Alaska Kast Konsole
Baseburners & Antiques: Glenwood #6, Glenwood #116


Re: A Word of Caution

PostBy: McGiever On: Wed. Jan. 18, 2017 10:05 pm

Is this the one?

Fields WMO-1 120 AC 200*F SPST Manual reset.
Designed for use with power venting and chimney vented systems for oil-fired applications.
McGiever
 
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Coal Size/Type: PEA / ANTHRACITE
Other Heating: Ground Source Heat Pump
Stove/Furnace Make: Hydro Heat /Mega Tek

Re: A Word of Caution

PostBy: philthy On: Wed. Jan. 18, 2017 10:13 pm

I believe so. I can verify Field Controls wmo-1 but not the rest. All it has is an address.
philthy
 
Hot Air Coal Stoker Stove: Keystoke Koker Lite, Alaska Kast Konsole
Baseburners & Antiques: Glenwood #6, Glenwood #116

Re: A Word of Caution

PostBy: freetown fred On: Wed. Jan. 18, 2017 10:43 pm

Good reminder P. Thanx!!