Ash Pan. How to Get #1 From #2

 
User avatar
Razzler
Member
Posts: 434
Joined: Wed. Dec. 19, 2007 7:56 pm
Location: Northampton Pa.
Stoker Coal Boiler: EFM DF520
Coal Size/Type: rice

Post by Razzler » Mon. Sep. 08, 2008 6:20 am

Fred put a rope through the pipe and pull the pex wile some feeds it, shouldn't be to bad. :flex:

 
User avatar
Yanche
Member
Posts: 3026
Joined: Fri. Dec. 23, 2005 12:45 pm
Location: Sykesville, Maryland
Stoker Coal Boiler: Alternate Heating Systems S-130
Coal Size/Type: Anthracite Pea

Post by Yanche » Mon. Sep. 08, 2008 11:53 am

I used 8" schedule 40 PVC pipe for my conduit. I've got two 1-1/2 inch insulated copper pipes plus PVC electrical conduit in it. It's got two 90 deg els in the run. I solved the problem of getting around the el by cutting the 8" PVC on my table saw in two. Like a clam shell. I glued half to the straight sections, pushed my pipe through and finished the copper el soldering with the top half of the clam shell off. When done I use RTV silicone to glue the top half on and to make up for the material removed by the saw kerf. Worked well.

 
User avatar
Freddy
Member
Posts: 7301
Joined: Fri. Apr. 11, 2008 2:54 pm
Location: Orrington, Maine
Stoker Coal Boiler: Axeman Anderson 130 (pea)
Coal Size/Type: Pea size, Superior, deep mined

Post by Freddy » Mon. Sep. 08, 2008 1:16 pm

Cool idea Yanche. It may come to that but I'm hopng to keep it one piece and have absolute water tightness. I checked today, no one has 6" flex unless I order a 250 foot roll. 6" shed 20 was only $14 a 10' length. It'll work! I'm going to have my four pex pipes, a 12/2 wire and I think I'll throw in a 6 ga wire to run my welder. Anything else I should add to the group?


 
User avatar
Blackdiamonddoug
Member
Posts: 328
Joined: Wed. Jun. 11, 2008 8:52 am
Location: haverhill Ma

Post by Blackdiamonddoug » Mon. Sep. 08, 2008 1:42 pm

Hi Freddy
How deep will the pipe be in the ground?
In Jackman at red buck cabins they get frost 12 feet deep.

BBD

 
User avatar
Freddy
Member
Posts: 7301
Joined: Fri. Apr. 11, 2008 2:54 pm
Location: Orrington, Maine
Stoker Coal Boiler: Axeman Anderson 130 (pea)
Coal Size/Type: Pea size, Superior, deep mined

Post by Freddy » Mon. Sep. 08, 2008 2:41 pm

Blackdiamonddoug wrote:In Jackman at red buck cabins they get frost 12 feet deep
Noooooo, even a few hundred miles north of Quebec frost only goes down 8 feet. Whoever told you they have 12 feet of frost in Maine was pulling your moose. Frost normally goes down four feet here. Northern Maine I don't believe would ever go over 6'. Maybe under a plowed driveway a bit deeper. Yikes! My pipes are going under my driveway! ;) I've planned the ditch to be 5 feet deep, top of pipe 4 1/2'. Two foot wide blue styofoam 2 or 3 inches above the pipe and I will not have an issue. I'll make it so if the garage moves a bit it won't bother the pipes. Thanks for the reminder though, 2 or 3 feet wouln't be enough.

 
User avatar
jimbo
Member
Posts: 109
Joined: Fri. Jun. 20, 2008 7:02 am
Location: Ephratah NY
Hand Fed Coal Furnace: Fire Chief 700
Coal Size/Type: Stove or nut
Contact:

Post by jimbo » Mon. Sep. 08, 2008 8:12 pm

Freddy
I ran a length of coaxal so I can use direct tv in the garage and a cat 5 cable for internet as well as cat 3 for phone for my small office I have out there along with a 12-3 with ground wire for a 3 way switch.


 
User avatar
218Bee
Member
Posts: 118
Joined: Wed. May. 07, 2008 10:19 pm
Location: Central, NY

Post by 218Bee » Mon. Sep. 08, 2008 9:41 pm

cat 5 cable for internet
+1 on cat 5 freddy..a laptop in the mancave :P

 
thepamperedlady
Member
Posts: 51
Joined: Fri. Sep. 12, 2008 10:46 am
Location: Rhode Island
Hot Air Coal Stoker Stove: Yes

Post by thepamperedlady » Mon. Sep. 15, 2008 12:54 pm

Hello,

Just a though, but we have a metal shop here in RI that has offered to make me a second ash pan for only $35.00. I just need to give them the dimensions, or bring the ash pan down and they will replicate it.

Maybe you all have a local company that may do the same?

-Emily