PostBy: traderfjp On: Sat Sep 20, 2008 11:24 pm

I was wondering what the TOTAL amps/volt that an Alaska 3 stove uses (combustion blower and DV motor and Blower). Also, in case of losing electricity and I go to battery backup I may not want to run my blower. Does anyone know how much juice I would conserve but turning it off?
traderfjp
 
Stove/Furnace Make: Alaska
Stove/Furnace Model: Channing 3

Re: Volts & Watts Drawn From Alaska DV

PostBy: Freddy On: Sun Sep 21, 2008 6:39 am

Can you get the the motors? Each motor should have a tag on it that tells the amps. I'm assuming voltage is 110/120.
Freddy
 
Stoker Coal Boiler: Axeman Anderson 130 (pea)
Hot Air Coal Stoker Stove: Reading piece o' junk in the barn (rice)
Coal Size/Type: Pea size, Superior, deep mined

Re: Volts & Watts Battery Backup

PostBy: traderfjp On: Sun Sep 21, 2008 7:43 am

Thanks Fred: I have a corner intall and with the fresh air, baro, and DV it's very hard to get to the motors. I was able to see one that said 200 watts. I'm thinking 600 watts total. But I'm not sure. I'm trying to figure out how long the two marine batteries I bought at Costco will last. I ran my electrical line too for the UPS. I was all set to use an extension cord and the guy at Lowes convinced me to use 12-2 MB-B. I bought a nipple that goes on the conduit so I could screw in an outlet and box. Then I ran the line through the outside of the house (about 2 feet) and into the boiler room in the basement. The wire goes about another 5' in conduit there is another outlet at the end. I'll use a small extension cord with two plugs from the outlet to the UPS for power. After I did all this I read that you shouldn't use MB in conduit and that I should have used strands of wire. I guess it stays cooler with out the jacket. I don't know but I'm just going to keep it. I can always rip it out when I sell if there is a problem.

Fred do you think I should use a GFI outlet by the stove or is that overkill? The current design has me connecting the marine batteries in series (I think) for 24 volts to satisfy the UPS and then it connects to the UPS. Any suggestions for fuses or is the house breaker enough?
traderfjp
 
Stove/Furnace Make: Alaska
Stove/Furnace Model: Channing 3


Re: Volts & Watts Drawn From Alaska DV

PostBy: WNY On: Sun Sep 21, 2008 8:29 am

Power (Watts) = I (Current) x V (Voltage)

So you can divide or multiply to figure out what you need. So, 200 Watts

200 W / V (120 Volts) = 1.6amps (approx).
WNY
 
Hot Air Coal Stoker Stove: Keystoker 90K, Leisure Line Hyfire I
Coal Size/Type: Rice
Stove/Furnace Make: Keystoker, LL & CoalTrol
Stove/Furnace Model: 90K, Hyfire I, VF3000 Soon

Re: Volts & Watts Drawn From Alaska DV

PostBy: kjb197 On: Sun Sep 21, 2008 12:06 pm

I was told you don't want motors on a GFCI. But you must have them in an unfinished basement (washer, dehumidifier?), bathroom (exhaust fan?), kitchen counters (blender, mixer?) etc. I wouldn't worry about it either way. Alot of computer equipment where I work is on UPS fed through GFCI extension cords.
kjb197
 
Stove/Furnace Make: Alaska
Stove/Furnace Model: Channing III

Re: Volts & Watts Drawn From Alaska DV

PostBy: Freddy On: Sun Sep 21, 2008 7:21 pm

Some motors don't like GFI's....or some GFI's don't like motors. I don't think it'll hurt anything, but sometimes a motor will run for a while then trip. Unless it's close enough to take a shower while loading the stove, I'd skip the GFI.

Here's a bettery sketch for those that need to know.
Attachments
Batteries4.jpg
(94.3 KiB) Viewed 1 time
View: New PagePopup • Select:BBCode
[nepathumb]6467[/nepathumb]
Freddy
 
Stoker Coal Boiler: Axeman Anderson 130 (pea)
Hot Air Coal Stoker Stove: Reading piece o' junk in the barn (rice)
Coal Size/Type: Pea size, Superior, deep mined

Re: Volts & Watts Drawn From Alaska DV

PostBy: BIG BEAM On: Sun Sep 21, 2008 8:01 pm

WNY wrote:Power (Watts) = I (Current) x V (Voltage)

So you can divide or multiply to figure out what you need. So, 200 Watts

200 W / V (120 Volts) = 1.6amps (approx).



Or VxA=W. volts x amps = watts
DON
BIG BEAM
 
Stove/Furnace Make: USS Hot blast
Stove/Furnace Model: 1557M

Re: Volts & Watts Drawn From Alaska DV

PostBy: WNY On: Mon Sep 22, 2008 7:46 am

Thanks.
Yes, you have to check your UPS setup with a Volt meter, I know mine is 24 Vdc, so I would have to hook my batteries in SERIES as shown, If I wanted to udpate the built in batteries (don't last very long).

VxA=W

That is the same is what I said...
W(Watts) = A(amps) x V(Volts)
WNY
 
Hot Air Coal Stoker Stove: Keystoker 90K, Leisure Line Hyfire I
Coal Size/Type: Rice
Stove/Furnace Make: Keystoker, LL & CoalTrol
Stove/Furnace Model: 90K, Hyfire I, VF3000 Soon

Re: Volts & Watts Drawn From Alaska DV

PostBy: ntp71 On: Mon Sep 22, 2008 12:08 pm

Finding out how long your batteries should last is easy once you know the Total Amperage you are using in your system and if you also know the AmpHour rating of the battery which should be displayed on the battery.

If P=V * I
then I = P/V

If your Amps Total is 5 amps, and your AmpHour rating is 25AH then

25AH/5 Amps = 5 hours

Neal
ntp71
 
Hand Fed Coal Boiler: Reading Foundry Water Heater
Hot Air Coal Stoker Stove: Old Mill Mini Stoker with Keystoker Feed System
Baseburners & Antiques: Caloric UltraMatic Coal-Gas Range

Re: Volts & Watts Drawn From Alaska DV

PostBy: Freddy On: Mon Sep 22, 2008 1:35 pm

ntp71 wrote: your Amps Total is 5 amps, and your AmpHour rating is 25AH then

25AH/5 Amps = 5 hours


Math is good, but batteries are lead & acid and electrons that didn't go to school. If you figured half, you'd be close to what you'd actually get. You'll get a bit more than half, in the case shown I'd bet 3 hours. Also, if you join two 25 AH batteries in parrellel, you get a 12V 50 AH battery. If you wire them in series, you get one 24V 25AH battery.
Freddy
 
Stoker Coal Boiler: Axeman Anderson 130 (pea)
Hot Air Coal Stoker Stove: Reading piece o' junk in the barn (rice)
Coal Size/Type: Pea size, Superior, deep mined

Re: Volts & Watts Drawn From Alaska DV

PostBy: ntp71 On: Mon Sep 22, 2008 1:43 pm

Actually I may have explained a bit wrong..falling asleep in a Transmitters/Recievers Class at the moment.

Take your Power Total and divide by your Total Battery Volatge and that will give you your Total Current Draw.

Then divide AmpHours by Total Current Draw.

This doesnt include the efficiency of the motors...which I dont have time for...late for class.

Neal
ntp71
 
Hand Fed Coal Boiler: Reading Foundry Water Heater
Hot Air Coal Stoker Stove: Old Mill Mini Stoker with Keystoker Feed System
Baseburners & Antiques: Caloric UltraMatic Coal-Gas Range

Re: Volts & Watts Drawn From Alaska DV

PostBy: BIG BEAM On: Mon Sep 22, 2008 7:16 pm

Yeah 1/2 AH rating is about right.When they rate SLA batteries it is at a VERY low current.At higher currents the AH goes down.They have a name for it something affect.Li ions and nicd/nimh the affect isn't as bad.
DON
BIG BEAM
 
Stove/Furnace Make: USS Hot blast
Stove/Furnace Model: 1557M