You're talking big bucks. 6k for a boiler plus copper, fittings, piping for the radiant heat, baseboard heat, permits, etc. and that is without buying any coal. I would think 8-9k. Also, I would be worried if you only had coal heat and wanted to sell the house. I'm not sure how the bank would handle that. You're going to go for a lung. You only have a 1200 sq. ft. house to heat. I would put in a coal stove 2-3k total costs or less if u buy used in the summer and save the money. We heat a 2k sq. ft. house and we can re-create tahiti, in our house, on the coldest days if we want. Just an opinion we all have them. Good luck.
Last edited by traderfjp on Sun. Oct. 05, 2008 10:04 pm, edited 1 time in total.

 
User avatar
Flyer5
Member
Posts: 10376
Joined: Sun. Oct. 21, 2007 4:23 pm
Location: Montrose PA
Stoker Coal Boiler: Leisure Line WL110
Hot Air Coal Stoker Stove: Leisure Line Pioneer
Contact:

Post by Flyer5 » Sun. Oct. 05, 2008 9:39 pm

I have radiant floor heat for the last 5 yrs . Love it nice warm floors house is a toasty 69-70 degrees . I don't have any insulation between the joists it also keeps my basement warm as well sometimes a little to well . I use it as a workshop it has 10' ceilings . I may do every other joist this year with the foil bubble insulation,if I get time . The nice thing is when you open a door the cold air comes in , as soon as the door is closed its warm again . I am surprised how warm it keeps the basement floor from 11'ft away . I don't have tubing in the concrete but I do have plastic + 2" insulation under it . You will love it if you decide to go with it . FYI ,It also makes it a lot easier to install the tubing when its warm less chance of kinking . Dave

 
cantman
New Member
Posts: 13
Joined: Sat. Oct. 04, 2008 3:45 pm
Location: Bucks County, Pennsylvania

Post by cantman » Sun. Oct. 05, 2008 9:58 pm

I'm really looking for an alternative to our current set-up. I really don't think I want a free standing or insert stove
for heat as we don't really have the extra space for a free standing and don't want the fireplace taken up with a insert.
Oh well, I'm in the planning stage and all ideas are always welcome.

Thanks for the great info!

 
User avatar
traderfjp
Member
Posts: 1801
Joined: Wed. Apr. 19, 2006 10:32 pm
Location: New York

Post by traderfjp » Sun. Oct. 05, 2008 10:06 pm

You can put it in the basement and install a custom coil. My coil heats my basement and would do your floors. You could pipe it into your existing hot air system.


 
cantman
New Member
Posts: 13
Joined: Sat. Oct. 04, 2008 3:45 pm
Location: Bucks County, Pennsylvania

Post by cantman » Sun. Oct. 05, 2008 10:55 pm

You can put it in the basement and install a custom coil. My coil heats my basement and would do your floors. You could pipe it into your existing hot air system
Interesting......very interesting....hmmmm....

So a coil would have the capability and output enough hot water to supply radiant floor heat plus a water to air exchanger system? This also sounds like
a great idea!

Thanks, this forum is great and the help has been stellar!

 
User avatar
traderfjp
Member
Posts: 1801
Joined: Wed. Apr. 19, 2006 10:32 pm
Location: New York

Post by traderfjp » Sun. Oct. 05, 2008 11:01 pm

Reading sells an oversized stove with a 250 lb hopper that may do what you want. Leisure LIne sells one too. Good luck and weigh all your options. Just getting a boiler into your basement will be a task.

 
User avatar
LsFarm
Member
Posts: 7383
Joined: Sun. Nov. 20, 2005 8:02 pm
Location: Michigan
Stoker Coal Boiler: Axeman Anderson 260
Hand Fed Coal Boiler: Self-built 'Big Bertha' SS Boiler
Baseburners & Antiques: Keystone 11, Art Garland

Post by LsFarm » Sun. Oct. 05, 2008 11:55 pm

No, you will not get enough heat out of a stoker stove with a hot water coil to heat radiant floor and baseboard.. look at the surface area for a coil to absorb heat from the coal fire in a stove.. just the surface area of a 1" tube about 3-4' long.. Then look at the heated surface area in a boiler.. there is no comparrison.

A coil can augment hot water heaters, and in some limited ways act like a boiler.. but in limited ways.. you cannot make a stove into a boiler..

If you can find a used stove to use this year, it will pay for itself.. then as you explore all your options for 'the ultimate central heating system' you can sell the stove at a later date..

Take care,, Greg L

.