i am installing a newyorker wood/coal unit. I want the controls to be seperate from the oil boiler its being plumbed to. I plan on using a L4006B for overheat, but which aquastat should I use in conjuction with a thermostat? the new yorker has a draft blower on it, I will need to control it and the circulator.
- Freddy
- Member
- Posts: 7301
- Joined: Fri. Apr. 11, 2008 2:54 pm
- Location: Orrington, Maine
- Stoker Coal Boiler: Axeman Anderson 130 (pea)
- Coal Size/Type: Pea size, Superior, deep mined
A Honeywell L8124C will do high & low with a differential and also use a thermostat and run a circulator....maybe even an L8124 A or B would suit you. I can't remember the difference in the details. I'm not sure what control is used to run a draft inducer. I think they come with their own seperate control.
-
- Member
- Posts: 40
- Joined: Sat. Jun. 07, 2008 7:28 am
well I figure the draft blower would get connected to where you would connect the burner motor....the way I see it is the draft blower would run up to like 180 or so, then back on at 160......just like the burner.