does anyone use a digital thermostat or know if there is 24 volts comming from thermostat terminals on stove control to run a digital thermostat? I am using the mercury one that came with my Harman Mag stoker and it seems there is a big variance gap in temp setting I just took notice know I just tapped thermostat soft now stove turned off is there any problems with these thermostats can I use a digital one ...if so what kind can or should I get...
-
- New Member
- Posts: 11
- Joined: Sun. Feb. 10, 2008 6:43 pm
I tied my magnum stoker into a digital thermostat. It's just needs a regular open then closed circuit. I did have to remove the jumper from the poles of my t-stat and that was it really was a piece of cake.
-
- Member
- Posts: 93
- Joined: Mon. Apr. 09, 2007 10:18 am
did thermostat work better than original with keeping temp more consistant ? what wire did u have to remove can I asked what thermostat u have...does stove supply power for digital display
-
- New Member
- Posts: 11
- Joined: Sun. Feb. 10, 2008 6:43 pm
Yes the thermostat I have is one of those intelligent ones that learns how long it takes for the heat and it cylces the stove on and off to keep the temp even. I have electric baseboard heat so the thermostat I have is for my central AC. Now it's a Honeywell tstat, right now it gets power off the air handler, but it also has 2AA batteries that you can run it off of. Honestly the tstat setup was the easiest part of the stove setup. If I can help anymore let me know.
-
- New Member
- Posts: 11
- Joined: Sun. Feb. 10, 2008 6:43 pm
On more thing here is the thermostat I use.
-
- New Member
- Posts: 11
- Joined: Sun. Feb. 10, 2008 6:43 pm
Sorry. The Honeywell TH6110D1005.
- WNY
- Member
- Posts: 6307
- Joined: Mon. Nov. 14, 2005 8:40 am
- Location: Cuba, NY
- Hot Air Coal Stoker Stove: Keystoker 90K, Leisure Line Hyfire I
- Coal Size/Type: Rice
- Contact:
It would probably work, if you have the standard Honewell Dial Type, I think most are 24VAC.
Kinda pricey, you can get a standard LUX type at Value home centers for like $24 on sale with setbacks.
Kinda pricey, you can get a standard LUX type at Value home centers for like $24 on sale with setbacks.
-
- Member
- Posts: 93
- Joined: Mon. Apr. 09, 2007 10:18 am
so the stove timer box asm on my Harman mag should supply 24 volts on one of the 2 terminals ....this then should power thermostat without batteries
-
- New Member
- Posts: 11
- Joined: Sun. Feb. 10, 2008 6:43 pm
I would say yes. Because if you disconnect the terminal leads on the timer box and jump the terminals on the box together the box runs like its trying to satisfy a tstat. Does this make sense.
-
- Member
- Posts: 93
- Joined: Mon. Apr. 09, 2007 10:18 am
Thanks Stephen I didnt know if it had voltage I just didnt want to burn timer box out thanks for helping me out ...
-
- New Member
- Posts: 11
- Joined: Sun. Feb. 10, 2008 6:43 pm
No problem. Good luck. I have learned a lot reading this forum and have been lurking for a long time.