I have a power vented Alaska Channing 3. It seems that all the heat is being sucked out the power vent. I have the vent almost closed off. Is there anything else I can do to help it? My dad has an AC3 as well (vented through a chimney) and it seems to put out twice the heat. Any advice would be appreciated!


 
User avatar
WNY
Member
Posts: 6307
Joined: Mon. Nov. 14, 2005 8:40 am
Location: Cuba, NY
Hot Air Coal Stoker Stove: Keystoker 90K, Leisure Line Hyfire I
Coal Size/Type: Rice
Contact:

Post by WNY » Tue. Nov. 11, 2008 9:43 am

You need to check the draft of your stove with a manometer and then you can adjust the baro and/or speed of the power venter if you hook up a rheostat. This has been discussed numerous times, just do a search on Power Venter speed control.