I Need Help Again

Post Reply
 
User avatar
Robby
Member
Posts: 81
Joined: Sat. Jan. 12, 2008 10:29 pm

Post by Robby » Thu. Dec. 04, 2008 12:28 am

I wish to now add 1100 gallon hot water storage.( evacuated solar to heat in late spring etc). Got the tank. Boiler to tank and return. Heating system from tank and return. How do I control the boiler to storage tank pump. If I turn on with an aquastat it will continue to run until storage is below set point! How do I tell the pump boiler is lit - start pumping, boiler is out - shut off. Got me stumped???? :?

Robby

 
User avatar
Freddy
Member
Posts: 7301
Joined: Fri. Apr. 11, 2008 2:54 pm
Location: Orrington, Maine
Stoker Coal Boiler: Axeman Anderson 130 (pea)
Coal Size/Type: Pea size, Superior, deep mined

Post by Freddy » Thu. Dec. 04, 2008 5:50 am

Per usual, I'm a bit confused. Why heat this huge tank with an oil burner?
Robby wrote:How do I tell the pump boiler is lit
If all you want to do is have the pump run while the oil burner is running, just hook the pump to the burner wires. Burner comes on, pump comes on, burner shuts off, pump shuts off.

 
User avatar
Dallas
Member
Posts: 746
Joined: Mon. Nov. 12, 2007 12:14 pm
Location: NE-PA
Hand Fed Coal Stove: Modified Russo C-35
Other Heating: Oil Hot Air

Post by Dallas » Thu. Dec. 04, 2008 10:23 am

I don't exactly see the picture ... give us a bit more of an idea what you are trying to do.

My thoughts are, that you might need a "differential controller", typically used with solar applications.


 
User avatar
coalmeister
Member
Posts: 668
Joined: Fri. May. 23, 2008 3:13 pm
Location: Between Rochester & Buffalo NY

Post by coalmeister » Thu. Dec. 04, 2008 12:27 pm

I would think you need an aquastat on the tank or, just over ride until the tank is heated up then just use it with the present control system and insulate the heck out of the tank

 
User avatar
JB Sparks
Member
Posts: 842
Joined: Sun. Oct. 19, 2008 8:09 pm
Location: north central Mass.

Post by JB Sparks » Thu. Dec. 04, 2008 6:17 pm

Not quite got the picture of what your trying to do, but if your going to heat up water in a steel tank make sure you put an expantion tank somewhere in that circuit.
JB