PostBy: heatwithcoal On: Thu Jan 29, 2009 9:17 am

I've always known about the ability to turn on the room-air fan (MANFAN) but have not really used it that much until this week. (I think this is the "coal burning as a hobby" part) What a difference! The house temp increasing by at least 3* just by running it for maybe 45min without using more coal. My stove will be at 425-450* then I turn on the MANFAN and the heat washes off the stove dropping it to about maybe 350*. (This is on a LL Econo I) I also noticed that the temp in my bedroom at the other end of the house gains a few degrees and is a more comfortable 69*.

Mark
User avatar
heatwithcoal
Member
 
Posts: 209
Joined: Wed Sep 12, 2007 9:48 pm
Location: Western Massachusetts
Stove/Furnace Make: Leisure Line
Stove/Furnace Model: AK-110


Re: MANFAN..What a Difference

PostBy: WNY On: Thu Jan 29, 2009 9:54 am

Yes, I use mine all the time to heat it up faster in the room, I put on maybe 40-50%+ to move a bit more air around when it on low.

I have a 3rd fan for my bonnet/jacket that normally runs most of the time to keep the stove sides cool, so it really helps move the air around too. it is on a temp switch around 120.
User avatar
WNY
Site Moderator
 
Posts: 5452
Joined: Mon Nov 14, 2005 9:40 am
Location: Cuba, NY
Stove/Furnace Make: Keystoker, LL & CoalTrol
Stove/Furnace Model: 90K, Hyfire I, VF3000 Soon

Re: MANFAN..What a Difference

PostBy: tvb On: Thu Jan 29, 2009 10:36 am

Ummmm, what's a manfan?
User avatar
tvb
Member
 
Posts: 1095
Joined: Sun Dec 02, 2007 9:13 pm
Stove/Furnace Make: Alaska
Stove/Furnace Model: Channing III

Re: MANFAN..What a Difference

PostBy: Devil505 On: Thu Jan 29, 2009 10:40 am

I'm confused too?? Are you talking about a blower fan on your stove?
User avatar
Devil505
Banned
 
Posts: 7227
Joined: Tue Jul 03, 2007 10:44 pm
Location: SE Massachusetts
Stove/Furnace Make: Harman
Stove/Furnace Model: TLC-2000

Re: MANFAN..What a Difference

PostBy: WNY On: Thu Jan 29, 2009 11:05 am

It is a SETTING in the COALTROL, that's why they posted in this section. If you don't have one, you wouldn't know.

it is called MANUAL FAN (MANFAN) Override. The fan speeds are normally Automatic based feed rate, as the feed rate increases, so does the fan speed.

BUT, sometimes, you just want a little more heat before the stove gets cranking. So, you can control the speed (0-99%) manually. :)
User avatar
WNY
Site Moderator
 
Posts: 5452
Joined: Mon Nov 14, 2005 9:40 am
Location: Cuba, NY
Stove/Furnace Make: Keystoker, LL & CoalTrol
Stove/Furnace Model: 90K, Hyfire I, VF3000 Soon