I'm starting to pump my boiler. Used 1 inch pex al pex to 1 1/4 black iron. Because of where I have to get to on both ends I will be useing around 12 to 14- 90's. Is there anyway of makeing soft 90's as compaired to a hard 90? My run is 60 feet with 8' rise. Closed loop with 2 plate heat exchangers and like I say 14 90's could someone suggest a circulation pump. Either single speed or 3 speed. Thanks Brian

 
CapeCoaler
Member
Posts: 6515
Joined: Sun. Feb. 10, 2008 3:48 pm
Location: Cape Cod, MA
Stoker Coal Boiler: want AA130
Hand Fed Coal Stove: DS Machine BS#4, Harman MKII, Hitzer 503,...
Coal Size/Type: Pea/Nut/Stove

Post by CapeCoaler » Sat. Jan. 31, 2009 10:52 am

Could the Pex not have been snaked to get past the area where the 90's are?
A picture or diagram of the area would generate some alternatives.

 
User avatar
steamup
Member
Posts: 1209
Joined: Fri. Oct. 03, 2008 12:13 pm
Location: Napoli, NY
Stoker Coal Boiler: Axeman-Anderson AA-130, Keystoker K-6
Hand Fed Coal Boiler: HS Tarm 502 Wood/Coal/Oil
Coal Size/Type: pea, buck, rice

Post by steamup » Mon. Feb. 02, 2009 1:30 pm

According to my charts, a 1-1/4" short radius 90 is equivalent to 3.3 feet of pipe from a pumping standpoint.

Are your heat exchangers series or parallel? The manufacturer of the heat exchanger should be able to give you a pressure drop through them.


 
26Weeks
Member
Posts: 108
Joined: Mon. Apr. 14, 2008 5:04 pm

Post by 26Weeks » Tue. Feb. 03, 2009 9:49 am

Can you bend pex al pex when its 15 degrees? I could save some fittings that way. Other than that I am stubbed just about 2 feet inside the house and have 15 to go. Also pex seems to like there fittings as compared to the price black iron. The dhw will be preheated as it heads for the propane hot water tank. Then mixed with cold for proper temp. with a mixing valve. The return line to the propane boiler will be T and through a heat exchanger to be preheated. Brian

 
CapeCoaler
Member
Posts: 6515
Joined: Sun. Feb. 10, 2008 3:48 pm
Location: Cape Cod, MA
Stoker Coal Boiler: want AA130
Hand Fed Coal Stove: DS Machine BS#4, Harman MKII, Hitzer 503,...
Coal Size/Type: Pea/Nut/Stove

Post by CapeCoaler » Tue. Feb. 03, 2009 2:23 pm

Heat is needed!