Thermostat info

Thermostat info

PostBy: ihatewood On: Sun Oct 07, 2012 1:17 pm

Looking for info on hooking up honeywell T87K manuel thermostat to Harmon magnum stoker, hook up point on Harmon control box has no markings as far as I know. Any particulaer way to hook up with polarity etc. Thanks in advance.
ihatewood
Member
 
Posts: 30
Joined: Thu Jan 20, 2011 10:28 pm
Location: Factoryville PA.
Stove/Furnace Make: Harmon Magnum stoker


Re: Thermostat info

PostBy: RAYJAY On: Sun Oct 07, 2012 5:07 pm

its just bell wire 2 conductor

and here is a link to the stove manual in pdf format

http://www.speedfreaksgarage.com/jeff/s ... Stoker.pdf
Attachments
col stove burn crop 004.jpg
(227.69 KiB) Viewed 8 times
View: New PagePopup • Select:BBCode
[nepathumb]36969[/nepathumb]
User avatar
RAYJAY
Member
 
Posts: 345
Joined: Sun Nov 09, 2008 8:06 am
Location: UNION DALE PA
Stove/Furnace Make: VAN WERT/ HARMAN /
Stove/Furnace Model: 600VA / MAGUM STOKER /

Re: Thermostat info

PostBy: ihatewood On: Sun Oct 07, 2012 7:55 pm

Thanks for info but does it matter how it is hooked up in thermostat R or W. I guess not but what about lugs on stove.
ihatewood
Member
 
Posts: 30
Joined: Thu Jan 20, 2011 10:28 pm
Location: Factoryville PA.
Stove/Furnace Make: Harmon Magnum stoker

Re: Thermostat info

PostBy: RAYJAY On: Mon Oct 08, 2012 12:39 am

The thermostat connections on the back panel of the Stoker Control are .25 inch male quick connect terminals. The mating connectors (supplied) should be .25 inch female quick connector terminals. The wire should be no smaller than 22 gauge.
The thermostat connections should only be connected across the thermostat switch inside the thermostat unit. This switch is the type which opens (turns off) when the set point temperature is reached, and closes (turns on) when the room temperature falls below the temperature. (This is the type supplied with the unit.

on the Thermostat

1. Loosen screw terminals, insert wires into terminal block, then re-tighten screws.
2. Push excess wire back into the wall opening.
3. Plug the wall opening with nonflammable insulation to prevent drafts from affecting thermostat operation.
Wiring
NOTES
R & Rc terminals (T87N)
In single-transformer system, leave metal jumper in place between R & Rc. Remove metal jumper if two-transformer system.
Heat pump systems (T87N)
If wiring to a heat pump, use a small piece of wire (not supplied) to connect terminals W and Y.
Wire specifications
Use 18-gauge thermostat wire. Shielded cable is not required.
Wallplate installation
Terminal Designations—T87N
W Heat relay.
Y Compressor contactor.
G Fan relay.
O Heat pump changeover valve energized in cooling.
Rc Cooling power. Connect to secondary side of cooling system transformer.
R Heating power. Connect to secondary side of heating system transformer.
B Heat pump changeover valve energized in heating.




hope this helps

i use a hunter model 42999b works great and there cheap get them at wally world IRC cost was around 20 bucks i hve 2 of them one on my gas heat in garage and one on the stoker

http://www.hunterair.com/product/just-r ... t-b-42999B
User avatar
RAYJAY
Member
 
Posts: 345
Joined: Sun Nov 09, 2008 8:06 am
Location: UNION DALE PA
Stove/Furnace Make: VAN WERT/ HARMAN /
Stove/Furnace Model: 600VA / MAGUM STOKER /

Re: Thermostat info

PostBy: McGiever On: Tue Oct 09, 2012 9:28 pm

ihatewood wrote:Thanks for info but does it matter how it is hooked up in thermostat R or W. I guess not but what about lugs on stove.



Nothing is polarity sensitive...does NOT matter. :)

A t'stat in just a simple switch for on or off operation. ;)