Wiz wrote:joia24 wrote:Pacowy wrote:If the pusher is moving and the coal is "backing up" behind the fire, that sounds like a problem I had with a flat grate stoker when I switched coals to a red ash coal that made such big clinkers that they wouldn't slide easily off the grate. This produced a lot of "plowing", with unburned coal going over the side of the grate "uphill" from the fire.
Also, if this problem came up right after you lit the fire, is there any chance that something you used to start the fire is stuck on the grate and backing up the coal?
Good luck.
Mike
Yes, I think it was the mouse I used to light the coal sticking to the grate. Today, unusually, nothing would lite the fire. I finally wore out. Even tried soaked coal as a starter to no avail. Tomorrow is a new day. Thanks for your help.
So now you have 2 issues, coal will not light and coal doesn't slide across grate. After reading your first post I keep looking at statement of cleaning prior to lighting first time.. I would suggest inspecting grates again, by following manual A. Remove combustion blower. Vacuum from under grate chamber.
B. Remove nut and bolt from bottom of grate, tap grates in upward direction. Lift
grate out vacuum chamber. Clear unit and grate of old furnace cement. Any
blocked holes may be opened with a 1/8 punch. Gently tap punch with
hammer. Re-cement grates to create an air tight fit from start of holes to top of
grate
oilman wrote:It sounds like you are not getting air to the fire for some reason. I am in your area if you want someone to talk to call me at 585-554-4492