PostBy: daluds On: Sat Nov 24, 2012 1:39 pm

The side where the blowers feeds into the pot is getting more air, and burning the coal unevenly. Is there a way to equalize the air flow? I didn't see any way to do this from the diagrams.

Thanks,

Dave
daluds
 
Stoker Coal Boiler: EFM DF520
Coal Size/Type: Rice
Stove/Furnace Make: EMF
Stove/Furnace Model: DF-520

Re: More air out of right side of pot

PostBy: Scottscoaled On: Sat Nov 24, 2012 4:58 pm

Sounds to me like you have either fines built upon the other side of the pot, or your bottom plate isn't seated right/warped. I would open the ashpan door and take out the ashpan. Without the stoker running of course. Look up under there and have someone pull the fines handle. You should be able to see into the holes in the bottom that get uncovered by the plate. See if there is a fine buildup in there. That is a good place to start. Then see if the bottom plate closes properly, tight to the bottom. Make sure it isn't warped. Get the easy stuff out of the way first :)
Scottscoaled
 
Stoker Coal Boiler: EFM 520x4, 350, 700. Van Wert 400 x 2, 800, 1200.
Coal Size/Type: Lots of buck

Re: More air out of right side of pot

PostBy: Rob R. On: Sat Nov 24, 2012 5:10 pm

Pull the cleanout lever at least once before you slide under there, and wear safety glasses. :)
Rob R.
 
Stoker Coal Boiler: EFM DF520
Coal Size/Type: Rice/buck
Other Heating: Dad's 1953 EFM Highboy

Re: More air out of right side of pot

PostBy: daluds On: Fri Nov 30, 2012 9:39 pm

Actually, its the left side that burns more than the right side when looking into the boiler, i.e. as the air exits the blower mounted on the right side it seems to come straight up into the pot.

It worked fine until I put in a new bushing and scrapped off a ton of ash on the inside of the boiler, but I also used compressed air and dust collector to blow/suck out the fines in the pot. Lots of fines came out. I was actually surprised there was so much in there. I'll shut it down tomorrow, and put a camera probe up there to look around. I'm going to remove the draft inducer from the smoke stack since I believe there is more natural draft since I scrapped off all the deposits on the inside of the boiler.

I'm considering taking the pot out and cleaning/rebuilding it. Is there a kit to buy? Thanks.

Dave
daluds
 
Stoker Coal Boiler: EFM DF520
Coal Size/Type: Rice
Stove/Furnace Make: EMF
Stove/Furnace Model: DF-520

Re: More air out of right side of pot

PostBy: stoker-man On: Sat Dec 01, 2012 12:05 am

There are three rope gaskets used in the pot. Maybe one is burned out and the air is pushing out. There is no kit to rebuild the pot. It's gaskets and burner plates.
stoker-man
 
Hand Fed Coal Boiler: 1981 efm wcb-24 in use 365 days a year
Coal Size/Type: Anthracite/Chestnut
Other Heating: Hearthstone wood stove

Re: More air out of right side of pot

PostBy: daluds On: Sun Dec 02, 2012 10:41 pm

Stoker-man,

How do I remove the burner from the blower to take out the pot to service? I can get the feed side disassembled, but I haven't taken the pot out yet.

Thanks,

Dave
daluds
 
Stoker Coal Boiler: EFM DF520
Coal Size/Type: Rice
Stove/Furnace Make: EMF
Stove/Furnace Model: DF-520

Re: More air out of right side of pot

PostBy: stoker-man On: Mon Dec 03, 2012 6:21 am

You will see a 3" air pipe between the pot and the blower. Loosen or remove the set screws at one end, pull straight out 1/2" and then twist. The stoker end of the pipe has the set screws at the mounting area of the stoker. Remove the coal pipe and the clean out lever.
stoker-man
 
Hand Fed Coal Boiler: 1981 efm wcb-24 in use 365 days a year
Coal Size/Type: Anthracite/Chestnut
Other Heating: Hearthstone wood stove

Re: More air out of right side of pot

PostBy: Rob R. On: Mon Dec 03, 2012 6:28 am

Dave, I don't mean to imply that you can't fix this yourself...but it seems like you have been struggling with this stoker for quite a while. Maybe it is time to take the entire pot assembly to an experienced EFM dealer and have a fresh set of eyes look it over.
Rob R.
 
Stoker Coal Boiler: EFM DF520
Coal Size/Type: Rice/buck
Other Heating: Dad's 1953 EFM Highboy

Re: More air out of right side of pot

PostBy: daluds On: Wed Dec 05, 2012 9:44 pm

I'm ordering the ropes to take the burner apart, and if I still have problems I will send it to EFM dealer to fix. I just don't have anyone in the area to help fix it.

Thanks,

Dave
daluds
 
Stoker Coal Boiler: EFM DF520
Coal Size/Type: Rice
Stove/Furnace Make: EMF
Stove/Furnace Model: DF-520

Re: More air out of right side of pot

PostBy: daluds On: Sun Dec 09, 2012 9:03 pm

Switched to oil today. I'll work on getting the pot out later in the week.
daluds
 
Stoker Coal Boiler: EFM DF520
Coal Size/Type: Rice
Stove/Furnace Make: EMF
Stove/Furnace Model: DF-520

Re: More air out of right side of pot

PostBy: daluds On: Thu Dec 13, 2012 10:12 pm

Got the pot out today. I didn't realize the "tray" above the ash bin slide out, but otherwise it wasn't too difficult.

I am not sure where air is leaking, but here are some pictures of the burner open.
Attachments
IMG_5449_sm.jpg
(229.48 KiB) Viewed 44 times
View: New PagePopup • Select:BBCode
The rope or gasket is hard as a rock.
[nepathumb]38657[/nepathumb]
IMG_5447_sm.jpg
(254.06 KiB) Viewed 46 times
View: New PagePopup • Select:BBCode
[nepathumb]38658[/nepathumb]
daluds
 
Stoker Coal Boiler: EFM DF520
Coal Size/Type: Rice
Stove/Furnace Make: EMF
Stove/Furnace Model: DF-520

Re: More air out of right side of pot

PostBy: Rob R. On: Thu Dec 13, 2012 10:17 pm

Can you repost a pictute like the first with a flash or a light shining down the center?
Rob R.
 
Stoker Coal Boiler: EFM DF520
Coal Size/Type: Rice/buck
Other Heating: Dad's 1953 EFM Highboy

Re: More air out of right side of pot

PostBy: Rob R. On: Thu Dec 13, 2012 10:18 pm

Also, it looks like there may have been a buildup of fines on the backside of the plates?
Rob R.
 
Stoker Coal Boiler: EFM DF520
Coal Size/Type: Rice/buck
Other Heating: Dad's 1953 EFM Highboy

Re: More air out of right side of pot

PostBy: Scottscoaled On: Fri Dec 14, 2012 1:36 am

That's different :? Looks like your tube wasn't properly seated. Did you oil your coal?
Scottscoaled
 
Stoker Coal Boiler: EFM 520x4, 350, 700. Van Wert 400 x 2, 800, 1200.
Coal Size/Type: Lots of buck

Re: More air out of right side of pot

PostBy: daluds On: Fri Dec 14, 2012 10:24 pm

Not sure what you mean by oil the coal....

I'm going to put it back together, and clean out the blower. Hopefully, it will work as new. I found another big chunk of coal in the tube so I have to filter the coal. I think the fines from the wet coal are clogging it up. I chipped out a lot of hardened coal fines from around the bottom of the plates on the right side. I'll start setting the bags up off the palet to let some of the water drain before I dump it in the coal bin.

Dave
daluds
 
Stoker Coal Boiler: EFM DF520
Coal Size/Type: Rice
Stove/Furnace Make: EMF
Stove/Furnace Model: DF-520