Alaskan 2 stove

Alaskan 2 stove

PostBy: majstrohl On: Tue Jan 01, 2013 5:34 pm

alaskan2 stove.stove keeps on shutting down.i have direct vent.the pipe was cleaned and outside motor.fume box shutthe unit down.Setting on digital thermostat L 10 H 50.Can anybody help me with this problem.
majstrohl
New Member
 
Posts: 3
Joined: Sun Oct 28, 2012 11:10 pm
Stove/Furnace Make: Alaskan
Stove/Furnace Model: model140

Visit Lehigh Anthracite

Re: Alaskan 2 stove

PostBy: dcrane On: Tue Jan 01, 2013 9:03 pm

there are alot of electronics and safety devices on these suckers... have you read thoroughly the owners manual or troubleshooting section? I know electricity is very important for fans and motors and old or faulty wiring can glitch things up pretty easy. I assume you have all doors closed properly and nothing is compromising the air tightness (which could trip one of the door sensors or something). I would first try to review ALL your owners manual stuff carefully while we wait for someone to come on here who has experience with your exact unit. GL!
User avatar
dcrane
Crane Stove Rep.
 
Posts: 1075
Joined: Sun Apr 22, 2012 9:28 am
Location: Duxbury, MA./Hanson MA./Brockton, MA
Stove/Furnace Make: Crane
Stove/Furnace Model: Crane 44

Re: Alaskan 2 stove

PostBy: majstrohl On: Wed Jan 02, 2013 9:49 am

read everything.they recommend running at h 50.it seems like it is to hot and fume switch kicks in.i am running at h 35 know so far so good.i would like to fine out .from other people that has alaskan 2,direct vent what do they run at.
majstrohl
New Member
 
Posts: 3
Joined: Sun Oct 28, 2012 11:10 pm
Stove/Furnace Make: Alaskan
Stove/Furnace Model: model140

Re: Alaskan 2 stove

PostBy: majstrohl On: Mon Jan 07, 2013 1:01 pm

Alaskan 2 stove i am running at 40 H .no problems.i had at 35,38 doesn't keep up with the heat. 40 does.
majstrohl
New Member
 
Posts: 3
Joined: Sun Oct 28, 2012 11:10 pm
Stove/Furnace Make: Alaskan
Stove/Furnace Model: model140

Visit Lehigh Anthracite