I just bought a keystoker (used) its a direct vent model, the vent exits at the base...Is it safe or advisable to run it straight up out a chimney? or do I need to cut a hole in my wall...
keystokercny
 
Stove/Furnace Model: keystoker

Re: Keystoker set up

PostBy: keystokercny On: Mon Nov 25, 2013 11:13 pm

anybody?
keystokercny
 
Stove/Furnace Model: keystoker

Re: Keystoker set up

PostBy: tsb On: Mon Nov 25, 2013 11:27 pm

My home made boiler has the stack out at the bottom and
vents into a chimney. Don't see why yours wouldn't work.
Make sure you have a CO detector.
tsb
 
Stoker Coal Boiler: Binford 2000
Hot Air Coal Stoker Stove: LL Pioneer top vent
Hand Fed Coal Stove: Saey Hanover II

Visit Lehigh Anthracite

Re: Keystoker set up

PostBy: VigIIPeaBurner On: Mon Nov 25, 2013 11:29 pm

You should be able to remove the DV kit and hook it into your chimney. There might be some safety wiring associated with the DV kit - call Keystoker.
VigIIPeaBurner
 
Hot Air Coal Stoker Furnace: Keystoker Koker
Hand Fed Coal Stove: Vermont Casting Vigilant II 2310
Other Heating: #2 Oil Furnace

Re: Keystoker set up

PostBy: oliver power On: Tue Nov 26, 2013 7:33 am

My KEYSTOKER boiler goes directly into chimney. Not sure of your set-up. I don't see any reason you couldn't do the same.
oliver power
 
Stoker Coal Boiler: KEYSTOKER Kaa-2
Hand Fed Coal Stove: Hitzer 50-93 & 30-95, Vigilant (pre-Vigilant-II)
Baseburners & Antiques: MANY (Mostly when burning wood)
Stove/Furnace Make: HITZER / KEYSTOKER
Stove/Furnace Model: 50-93 & 30-95 , Kaa-2

Re: Keystoker set up

PostBy: Tobytech On: Wed Nov 27, 2013 1:10 am

I think if your could consistently get a correct manometer reading then you should be ok. In a sense you would still be double drafting the stove. On my 90k I have my power vent exhaust turned to its lowest setting and I'm at -.02 venting into ambient. Good luck and please post your results. Todd.
Tobytech
 
Stove/Furnace Make: Keystoker
Stove/Furnace Model: 90k

Re: Keystoker set up

PostBy: WNY On: Thu Nov 28, 2013 10:22 am

If you have existing chimney with a good draft, you can remove the Direct Vent and run it directly into your chimney. You will need a Baro Damper if not using your Direct Vent to adjust the draft correctly on the stove. You should have a draft gauge that you can adjust it correctly.

Running the DV up and into chimney is also ok. as long you don't have any other appliances sharing the same chimney, the DV could pressurize it and back feed into the other holes and come out somewhere else. Just be careful!

My keystoker is running a pipe up and outside, I had an existing hole in the wall near the ceiling and it runs up and over and outside.
WNY
 
Hot Air Coal Stoker Stove: Keystoker 90K, Leisure Line Hyfire I
Coal Size/Type: Rice
Stove/Furnace Make: Keystoker, LL & CoalTrol
Stove/Furnace Model: 90K, Hyfire I, VF3000 Soon