Post by lancenator09 » Fri. Dec. 31, 2010 2:04 pm

My VA-600 is overheating due to too much airflow. I have had to reduce the air and am wondering how to change the auger speed to prevent wasting coal in the ashes. I do not have an operator's manual, so I don't know how to adjust it. Does anyone know how to locate a manual or how to change the setting? Thanks in advance for any help.

 
User avatar
Richard S.
Mayor
Posts: 15227
Joined: Fri. Oct. 01, 2004 8:35 pm
Location: NEPA
Stoker Coal Boiler: Van Wert VA1200
Coal Size/Type: Buckwheat/Anthracite

Post by Richard S. » Fri. Dec. 31, 2010 2:23 pm

On the 1200 the only way to do this is by changing a pulley. Not sure about the 600 but the air adjustment is on the back, its the red slider partially seen to the left in this image:
What do you have the aquastat set at?

 
lancenator09
Member
Posts: 22
Joined: Sat. Nov. 08, 2008 7:01 pm
Stoker Coal Boiler: Van Wert
Other Heating: oil boiler

Post by lancenator09 » Fri. Dec. 31, 2010 5:47 pm

My aquastat is set at 190F for the high and at 150F for the low. It actually goes up to 200F after the fan shuts off and it goes down to about 140F. I guess the aquastats aren't exactly perfect with their settings.


 
User avatar
CoalHeat
Member
Posts: 8862
Joined: Sat. Feb. 10, 2007 9:48 pm
Location: Stillwater, New Jersey
Stoker Coal Boiler: 1959 EFM 350
Hand Fed Coal Stove: Harman Magnafire Mark I
Baseburners & Antiques: Sears Signal Oak 15 & Andes Kitchen Range
Coal Size/Type: Rice and Chestnut
Other Heating: Fisher Fireplace Insert

Post by CoalHeat » Fri. Dec. 31, 2010 6:31 pm

The aquastats are accurate, but the boiler can continue to heat the water after it shuts down. Aquastats incorporate a differential or "drift", for example a Honeywell triple aquastat with a low setting of 170° will not fire the stoker until the water temperature drops to 160°.
See page 5 on this:
http://customer.honeywell.com/techlit/pdf/PackedL ... 0-2553.pdf

 
bradglynn
New Member
Posts: 1
Joined: Sat. Apr. 19, 2014 12:29 am
Stoker Coal Boiler: van wert va600
Hand Fed Coal Boiler: no
Hot Air Coal Stoker Furnace: no
Coal Size/Type: buckwheat
Other Heating: back up oil

Post by bradglynn » Sat. Apr. 19, 2014 12:42 am

hello my name is Brad have a Van Wert va 600 it was in the house when I bought it they supposedly had it totally rebuilt 5 to 7 years ago now the ring that goes around the top of the pot that shakes back and forth broke does anyone know where I can buy one and also can I run the stove with this being broke without doing damage to any other parts on the stove also does anybody know the name of the part that I am looking for I believe it's called a rocker ring any help would be grateful thanks

 
User avatar
davidmcbeth3
Member
Posts: 8505
Joined: Sun. Jun. 14, 2009 2:31 pm
Coal Size/Type: nut/pea/anthra

Post by davidmcbeth3 » Sat. Apr. 19, 2014 3:47 am

Holy necroposting Batman !

Thread is 4 yrs old

welcome to the forum Brad

I have no help to give you ... maybe others could help .. a pic may aid folks


 
User avatar
windyhill4.2
Member
Posts: 6072
Joined: Fri. Nov. 22, 2013 2:17 pm
Location: Jonestown,Pa.17038
Stoker Coal Boiler: 1960 EFM520 installed in truck box
Hand Fed Coal Stove: Crane 404 with variable blower
Coal Size/Type: 404-nut, 520 rice ,anthracite for both

Post by windyhill4.2 » Sat. Apr. 19, 2014 6:41 am

That is an ash shaker,designed to break any clinkers that form,can be removed & boiler will operate just fine. Type restoration of Van Wert 400 into the search box ,Member Scottscoaled talks about the ring,very interesting rebuild .

 
User avatar
anthony7812
Member
Posts: 5152
Joined: Sat. Mar. 12, 2011 2:04 pm
Location: Colley,Pennsylvania
Stoker Coal Boiler: VanWert VA 400
Coal Size/Type: Buck/Anthracite

Post by anthony7812 » Sat. Apr. 19, 2014 8:02 am

The slicer is not necessary.

 
User avatar
Scottscoaled
Member
Posts: 2812
Joined: Tue. Jan. 08, 2008 9:51 pm
Location: Malta N.Y.
Stoker Coal Boiler: EFM 520, 700, Van Wert 800 GJ 61,53
Baseburners & Antiques: Magic Stewart 16, times 2!
Coal Size/Type: Lots of buck
Other Heating: Slant Fin electric boiler backup

Post by Scottscoaled » Sat. Apr. 19, 2014 3:55 pm

Yes, you can run that VW-600 very well with out the ash slice. A bolt on either side of the pot and it will come right off. Disconnect the linkage and plug the hole where it goes out to the stoker. That whole assembly isn't needed.