My New Crawford!

 
User avatar
nortcan
Member
Posts: 3146
Joined: Sat. Feb. 20, 2010 3:32 pm
Location: Qc Canada

Post by nortcan » Fri. Sep. 12, 2014 8:03 pm

Thanks for the warming photos. Always a pleasure to see the first fires of the ""year"".


 
scalabro
Member
Posts: 4197
Joined: Wed. Oct. 03, 2012 9:53 am
Location: Western Massachusetts
Baseburners & Antiques: Crawford 40, PP Stewart No. 14, Abendroth Bros "Record 40"
Coal Size/Type: Stove / Anthracite.
Other Heating: Oil fired, forced hot air.

Post by scalabro » Fri. Sep. 12, 2014 8:20 pm

Eight scoops now, I figure that's enough.

It stinks!

Another pic for you Nortcan.

Attachments

image.jpg

1st coal fire in the Crawford 40

.JPG | 111.7KB | image.jpg

 
User avatar
Sunny Boy
Member
Posts: 25567
Joined: Mon. Nov. 11, 2013 1:40 pm
Location: Central NY
Hand Fed Coal Boiler: Anthracite Industrial, domestic hot water heater
Baseburners & Antiques: Glenwood range 208, # 6 base heater, 2 Modern Oak 118.
Coal Size/Type: Nuts !
Other Heating: Oil &electric plenum furnace

Post by Sunny Boy » Fri. Sep. 12, 2014 9:00 pm

Now, that looks much better !!!!! :D

Paul

 
scalabro
Member
Posts: 4197
Joined: Wed. Oct. 03, 2012 9:53 am
Location: Western Massachusetts
Baseburners & Antiques: Crawford 40, PP Stewart No. 14, Abendroth Bros "Record 40"
Coal Size/Type: Stove / Anthracite.
Other Heating: Oil fired, forced hot air.

Post by scalabro » Sun. Sep. 14, 2014 2:28 pm

Ok...decided to finish what I started.

Watching the Giants & burning paint!

Check out the crazy good numbers in the pics :)

OAT = 70*

Draft = .08

Primary open 1/4

Secondary closed

MPD closed

Check closed

I think I'm going to have to use the check when it gets cold!

Attachments

image.jpg
.JPG | 103.6KB | image.jpg
image.jpg
.JPG | 139.1KB | image.jpg
image.jpg
.JPG | 160.6KB | image.jpg
image.jpg
.JPG | 171.3KB | image.jpg
image.jpg
.JPG | 108.9KB | image.jpg

 
User avatar
Sunny Boy
Member
Posts: 25567
Joined: Mon. Nov. 11, 2013 1:40 pm
Location: Central NY
Hand Fed Coal Boiler: Anthracite Industrial, domestic hot water heater
Baseburners & Antiques: Glenwood range 208, # 6 base heater, 2 Modern Oak 118.
Coal Size/Type: Nuts !
Other Heating: Oil &electric plenum furnace

Post by Sunny Boy » Sun. Sep. 14, 2014 2:53 pm

Wow ! .08 with the MPD closed. You may need two check dampers to slow that one down, :D

Paul

 
scalabro
Member
Posts: 4197
Joined: Wed. Oct. 03, 2012 9:53 am
Location: Western Massachusetts
Baseburners & Antiques: Crawford 40, PP Stewart No. 14, Abendroth Bros "Record 40"
Coal Size/Type: Stove / Anthracite.
Other Heating: Oil fired, forced hot air.

Post by scalabro » Sun. Sep. 14, 2014 3:01 pm

Sunny Boy wrote:Wow ! .08 with the MPD closed. You may need two check dampers to slow that one down, :D

Paul
Suck it AL29 liner haters!

:taz:

That's read after the MPD, but before the 90* turn up the chimney, with a Bacharach "Draft Rite" hand held gauge.

Maybe the Dwyer is more accurate?

I guess it's just chimney draft, not the draft applied to the stove.

I'll drill another hole before the damper after the game.

 
User avatar
DePippo79
Member
Posts: 734
Joined: Tue. Mar. 05, 2013 3:17 pm
Location: Hampton, NH
Baseburners & Antiques: Glenwood Oak 40, Stanley Argand No. 30, Glenwood Modern Oak 114, Stanley Argand No. 20 missing parts.
Coal Size/Type: Anthracite. Stove and nut size.
Other Heating: Oil hot water.

Post by DePippo79 » Sun. Sep. 14, 2014 3:18 pm

Nice. Glad I'm not the only one getting anxious and lighting off. Wish I didn't have work. Would really like to sit and enjoy the Stanley with my book. Oh well. Take care. Matt


 
User avatar
Lightning
Site Moderator
Posts: 14659
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Sun. Sep. 14, 2014 3:57 pm

Yes I agree.. it's more usable information if you measure the pressure of the stove.. doesn't really matter what the chimney is doing..

Putting the mano before the MPD will help you with setting it. :)

 
scalabro
Member
Posts: 4197
Joined: Wed. Oct. 03, 2012 9:53 am
Location: Western Massachusetts
Baseburners & Antiques: Crawford 40, PP Stewart No. 14, Abendroth Bros "Record 40"
Coal Size/Type: Stove / Anthracite.
Other Heating: Oil fired, forced hot air.

Post by scalabro » Sun. Sep. 14, 2014 5:08 pm

Thanks Matt! You will be warm in front of your stove in no time. I know what it's like to work weekends. Yesterday was a hard 12 hour side job.

Lee....I think I'm gonna wait till the stove is cold before I drill on the stack. Next report will have stove draft and chimney draft posted.

She's about 3/4 full, I'm going to let it run overnight.

 
User avatar
wsherrick
Member
Posts: 3744
Joined: Wed. Jun. 18, 2008 6:04 am
Location: High In The Poconos
Hand Fed Coal Stove: Glenwood Base Heater, Crawford Base Heater
Baseburners & Antiques: Crawford Base Heater, Glenwood, Stanley Argand
Coal Size/Type: Chestnut, Stove Size

Post by wsherrick » Sun. Sep. 14, 2014 6:31 pm

The stove will settle down once it gets an ash layer in it. That makes a big difference. In the fall and spring you simply need to figure out how much ash to keep in it. You'll figure it out.
Also the check damper should be able to knock that barrel temperature down in a hurry.

 
scalabro
Member
Posts: 4197
Joined: Wed. Oct. 03, 2012 9:53 am
Location: Western Massachusetts
Baseburners & Antiques: Crawford 40, PP Stewart No. 14, Abendroth Bros "Record 40"
Coal Size/Type: Stove / Anthracite.
Other Heating: Oil fired, forced hot air.

Post by scalabro » Sun. Sep. 14, 2014 7:00 pm

Good point William.

I never looked at it that way and it explains a lot.

Before I returned the No. 2 to the "Hospital," I blew it out in my driveway with my backpack leaf blower, to minimize ash in the van and to make life a little easier for Brandon.

I must have done that for a good five minutes before ALL the ash came out. This is in addition to using the ash vac every week or so during the winter.

Good thing I had a paint mask/respirator, my neighbors must have thought I'm a lunatic!

 
coalnewbie
Member
Posts: 8601
Joined: Sat. May. 24, 2008 4:26 pm
Location: Chester, NY
Hot Air Coal Stoker Stove: LL AnthraKing 180K, Pocono110K,KStokr 90K, DVC
Hand Fed Coal Stove: Invader 2
Baseburners & Antiques: Wings Best, Glenwood #8(x2) Herald 116x
Coal Size/Type: Rice,
Other Heating: Heating Oil CH, Toyotomi OM 22

Post by coalnewbie » Sun. Sep. 14, 2014 8:10 pm

I must have done that for a good five minutes before ALL the ash came out. This is in addition to using the ash vac every week or so during the winter.
Hmm I'm thinking that is THE protocol for a base heater. Those passageways do get really blocked up, my BB Red cross Garnet 48 was totally choked when I bought it and hey thought they had cleaned it. Disconnect, take it outside, leaf blower, blow in soda like Nortcan did with his air gun, damp rid, wrap it up and wait until fall to reinstall. PITA but that is how you start the season clean. Or keep the Hitzer 50-93 running, put in a fake light in the BBs and gaze at it all winter. Nah, William would have a fit and I would get hate mail forever. :)

I have been gazing at my Wings impatiently all summer and the fake Calumet light is a riot. Shelley is now giving me grief.... you are not going to get it dirty are you... how can you? .... :bang:

 
User avatar
wsherrick
Member
Posts: 3744
Joined: Wed. Jun. 18, 2008 6:04 am
Location: High In The Poconos
Hand Fed Coal Stove: Glenwood Base Heater, Crawford Base Heater
Baseburners & Antiques: Crawford Base Heater, Glenwood, Stanley Argand
Coal Size/Type: Chestnut, Stove Size

Post by wsherrick » Sun. Sep. 14, 2014 9:33 pm

coalnewbie wrote:
I must have done that for a good five minutes before ALL the ash came out. This is in addition to using the ash vac every week or so during the winter.
Hmm I'm thinking that is THE protocol for a base heater. Those passageways do get really blocked up, my BB Red cross Garnet 48 was totally choked when I bought it and hey thought they had cleaned it. Disconnect, take it outside, leaf blower, blow in soda like Nortcan did with his air gun, damp rid, wrap it up and wait until fall to reinstall. PITA but that is how you start the season clean. Or keep the Hitzer 50-93 running, put in a fake light in the BBs and gaze at it all winter. Nah, William would have a fit and I would get hate mail forever. :)

I have been gazing at my Wings impatiently all summer and the fake Calumet light is a riot. Shelley is now giving me grief.... you are not going to get it dirty are you... how can you? .... :bang:
We need to get that attitude adjusted pronto.
We are going to remember all of this angst next March after you have finally, at long last, struck the match and made the first fire in the base heater. We will all congratulate you once you realize that the base heaters have liberated you from a cold house and large expense. All of the second guessing and hand wringing we have been put through has got have a payoff at some point. We have been waiting for this moment for how long now?
You will not back out and cheat us of the big moment. Not an option there buddy.

 
scalabro
Member
Posts: 4197
Joined: Wed. Oct. 03, 2012 9:53 am
Location: Western Massachusetts
Baseburners & Antiques: Crawford 40, PP Stewart No. 14, Abendroth Bros "Record 40"
Coal Size/Type: Stove / Anthracite.
Other Heating: Oil fired, forced hot air.

Post by scalabro » Thu. Sep. 18, 2014 5:39 pm

So tonight is a bit chilly as already 67* and we may get a frost overnight. I drilled the hole in the stack before the MPD. Results are as follows...

OAT= 67*
Chimney draft = .08
Stove draft and MPD position as shown in picture
Upper Barrel = 400*
Lower barrel = 500*
Stack temp 1 foot after MPD = 200*
Check closed
Primary open 1/8 of an inch

Attachments

image.jpg

09/18/14

.JPG | 131.3KB | image.jpg

 
KingCoal
Member
Posts: 4837
Joined: Wed. Apr. 03, 2013 1:24 pm
Location: Elkhart county, IN.
Hand Fed Coal Stove: 1 comforter stove works all iron coal box stove, seventies.
Baseburners & Antiques: 2014 DTS C17 Base Burner, GW #6, GW 113 formerly Sir Williams, maybe others at Pauliewog’s I’ve forgotten about
Coal Size/Type: Nut Anth.
Other Heating: none

Post by KingCoal » Thu. Sep. 18, 2014 6:37 pm

cool,

where is "lower barrel" measurement being taken ?

stack temp. is pretty good.

can't really tell what the mano. is showing :(


Post Reply