Wiring a Heat Exchanger and Modine and Pump.

 
User avatar
hotblast1357
Member
Posts: 5661
Joined: Mon. Mar. 10, 2014 10:06 pm
Location: Peasleeville NY
Stoker Coal Boiler: 1984 Eshland S260 coal gun
Coal Size/Type: Lehigh anthracite pea
Other Heating: air source heat pump, oil furnace

Post by hotblast1357 » Sat. Aug. 29, 2015 7:11 pm

Lol hire someone?


 
User avatar
hotblast1357
Member
Posts: 5661
Joined: Mon. Mar. 10, 2014 10:06 pm
Location: Peasleeville NY
Stoker Coal Boiler: 1984 Eshland S260 coal gun
Coal Size/Type: Lehigh anthracite pea
Other Heating: air source heat pump, oil furnace

Post by hotblast1357 » Thu. Sep. 03, 2015 8:09 pm

Ok guys so I have a little issue.. I wired up the house fan and circulator to the thermostat, the fan works properly off from the internal relay that I used, but the pump relay, a Honeywell RA89A has a issue, when the thermostat calls it kicks the pump on, but when I turn down the t'stat the pump stays on until I kill the 120v to the relay?? It should shut off once I shut off the 24v connection?

 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Thu. Sep. 03, 2015 9:06 pm

24v t'stat turns on furnace fan and pump...2 different relays.

24v t'stat turns off furnace fan relay...but pump relay still runs.

Do I understand this correctly?

 
User avatar
hotblast1357
Member
Posts: 5661
Joined: Mon. Mar. 10, 2014 10:06 pm
Location: Peasleeville NY
Stoker Coal Boiler: 1984 Eshland S260 coal gun
Coal Size/Type: Lehigh anthracite pea
Other Heating: air source heat pump, oil furnace

Post by hotblast1357 » Fri. Sep. 04, 2015 8:56 am

Correct! Do I have to pump wired up wrong?

 
User avatar
hotblast1357
Member
Posts: 5661
Joined: Mon. Mar. 10, 2014 10:06 pm
Location: Peasleeville NY
Stoker Coal Boiler: 1984 Eshland S260 coal gun
Coal Size/Type: Lehigh anthracite pea
Other Heating: air source heat pump, oil furnace

Post by hotblast1357 » Sat. Sep. 05, 2015 3:19 pm

I've been messing with this all day and it just won't work right! Everything is turning everything on! Lol I've got modine relay in garage, power going in and out to modine fan 120v. and 24v Tstat wire from Tstat and wire going to pump relay inside and dump zone astat.

Second relay is for pump, I have the 24v Tstat wire from the garage and from the house tstat.

The furnace fan I am turning on with the Tstat.

Attachments

image.jpg

Garage relay

.JPG | 114.1KB | image.jpg
image.jpg

Pump relay

.JPG | 100.9KB | image.jpg

 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Sat. Sep. 05, 2015 6:08 pm

supply (line) only on 1 and 2

1 and 3 gets jumpered (factory done maybe)

pump and/or fan (load) goes on 2 and 4

 
User avatar
hotblast1357
Member
Posts: 5661
Joined: Mon. Mar. 10, 2014 10:06 pm
Location: Peasleeville NY
Stoker Coal Boiler: 1984 Eshland S260 coal gun
Coal Size/Type: Lehigh anthracite pea
Other Heating: air source heat pump, oil furnace

Post by hotblast1357 » Sat. Sep. 05, 2015 8:01 pm

Yup that's how I have it. The 24v lines are were I think my problem is, I tied them into eachother before the Tstats, so I think they are back feeding turning on other things.


 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Sat. Sep. 05, 2015 8:37 pm

120 v supply (line) only on 1 and 2...a black and a white.

1 and 3 gets jumpered (factory done maybe)

pump and/or fan (load) goes on 2 and 4

so, only need 1 wire on 1
2 wires on 2
and 1 wire on 4
hotblast1357 wrote:Yup that's how I have it. The 24v lines are were I think my problem is, I tied them into eachother before the Tstats, so I think they are back feeding turning on other things.
A t'stat is simply a single pole switch...makes and breaks the 24 volt line.

Image
Last edited by McGiever on Sat. Sep. 05, 2015 9:11 pm, edited 1 time in total.

 
User avatar
Scottscoaled
Member
Posts: 2812
Joined: Tue. Jan. 08, 2008 9:51 pm
Location: Malta N.Y.
Stoker Coal Boiler: EFM 520, 700, Van Wert 800 GJ 61,53
Baseburners & Antiques: Magic Stewart 16, times 2!
Coal Size/Type: Lots of buck
Other Heating: Slant Fin electric boiler backup

Post by Scottscoaled » Sat. Sep. 05, 2015 8:55 pm

You don't have the Honeywell RB845 B controllers. They are double pole relays. The ones you have are single pole. All it would have taken is just one call.

 
User avatar
hotblast1357
Member
Posts: 5661
Joined: Mon. Mar. 10, 2014 10:06 pm
Location: Peasleeville NY
Stoker Coal Boiler: 1984 Eshland S260 coal gun
Coal Size/Type: Lehigh anthracite pea
Other Heating: air source heat pump, oil furnace

Post by hotblast1357 » Sat. Sep. 05, 2015 8:57 pm

Here is a better pic, that's how there wired. Here's a scenario...

I turn the breaker on for the modine 120v. I turn the breaker on for the pump 120v and then they both come on, WITHOUT me turning on the Tstat. The 24v relays are getting powered on and idk how. But if I take 120v power away from the pump circuit I can control the modine with the Tstat. I have the dump zone astat unhooked to eliminate that even though I know it works.

Do I have to run Tstat wire from the Tstat to both the modine and the pump individually? The way I have it hooked is Tstat wire to relay for modine, then too pump relay. Not a separate pair of wires, one too modine, one too pump. I think right now everything is getting 24v.. I don't know how because the Tstats are off, I will have to check with my multi meter Wednesday when I can get it from work.

Attachments

image.jpg
.JPG | 109.6KB | image.jpg

 
User avatar
hotblast1357
Member
Posts: 5661
Joined: Mon. Mar. 10, 2014 10:06 pm
Location: Peasleeville NY
Stoker Coal Boiler: 1984 Eshland S260 coal gun
Coal Size/Type: Lehigh anthracite pea
Other Heating: air source heat pump, oil furnace

Post by hotblast1357 » Sun. Sep. 06, 2015 7:11 pm

So I think I just need to put some diode's in the Tstat wires so they don't back feed. I did not buy double pole relays, these are single which is why I'm having these problems isn't it?

 
User avatar
Rob R.
Site Moderator
Posts: 18004
Joined: Fri. Dec. 28, 2007 4:26 pm
Location: Chazy, NY
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Chubby Jr

Post by Rob R. » Sun. Sep. 06, 2015 8:19 pm

You are making this a lot more complex then it needs to be. Just call Scott.

I use the R845 style relays with an extra set of contacts, but there might be a way to make your current equipment work.

 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Sun. Sep. 06, 2015 9:46 pm

hotblast1357 wrote:So I think I just need to put some diode's in the Tstat wires so they don't back feed. I did not buy double pole relays, these are single which is why I'm having these problems isn't it?
Diodes are for blocking DC in one direction, not for blocking AC as it reverses it's polarity 60 times every second.

 
User avatar
hotblast1357
Member
Posts: 5661
Joined: Mon. Mar. 10, 2014 10:06 pm
Location: Peasleeville NY
Stoker Coal Boiler: 1984 Eshland S260 coal gun
Coal Size/Type: Lehigh anthracite pea
Other Heating: air source heat pump, oil furnace

Post by hotblast1357 » Mon. Sep. 07, 2015 4:50 am

Lol alrighty then, so I simply bought the wrong relays and there's no way of fixing these.

 
User avatar
Scottscoaled
Member
Posts: 2812
Joined: Tue. Jan. 08, 2008 9:51 pm
Location: Malta N.Y.
Stoker Coal Boiler: EFM 520, 700, Van Wert 800 GJ 61,53
Baseburners & Antiques: Magic Stewart 16, times 2!
Coal Size/Type: Lots of buck
Other Heating: Slant Fin electric boiler backup

Post by Scottscoaled » Mon. Sep. 07, 2015 8:08 am

Naw,,,,, you can use a couple RIB"S.


Post Reply