Battery Back for Boiler

 
Burning2nd
New Member
Posts: 10
Joined: Wed. Jun. 17, 2015 9:52 pm
Location: Effort Pa
Stoker Coal Boiler: Keystoker 90

Post by Burning2nd » Thu. Jun. 18, 2015 1:04 pm

Image

This is what I intend on puting on my keystoker... I have several of them thru out the house.. (computer work station, CCTV systm, quadraFire pellet stove)

It will with out a doubt give you a few hours of run time while you get the generator out and setup... (assuming you loose power frequently )

its A cyberpower brand UPS

just select the size of the one for your application.. depending on draw

 
User avatar
hotblast1357
Member
Posts: 5657
Joined: Mon. Mar. 10, 2014 10:06 pm
Location: Peasleeville NY
Stoker Coal Boiler: 1984 Eshland S260 coal gun
Coal Size/Type: Lehigh anthracite pea
Other Heating: air source heat pump, oil furnace

Post by hotblast1357 » Thu. Jun. 18, 2015 1:40 pm

Thanks for that, if I can go with the non electric zone though I will.

 
CoaldHeat
Member
Posts: 41
Joined: Wed. Jan. 29, 2014 7:44 am
Location: Waterford, CT
Hot Air Coal Stoker Stove: LL Pioneer LE/T
Coal Size/Type: Rice

Post by CoaldHeat » Mon. Jul. 06, 2015 12:36 pm

Anything in this post that may help?

A Battery Backup for My Pocono


 
User avatar
hotblast1357
Member
Posts: 5657
Joined: Mon. Mar. 10, 2014 10:06 pm
Location: Peasleeville NY
Stoker Coal Boiler: 1984 Eshland S260 coal gun
Coal Size/Type: Lehigh anthracite pea
Other Heating: air source heat pump, oil furnace

Post by hotblast1357 » Sun. Oct. 04, 2015 7:30 am

well guys ive been lit for 8 days straight now, burning for DHW, and had two heat calls yesterday morning, so right now I would of thought would be the time that my dump zone would be working, it has only dumped twice since ive been lit and for about 45 seconds each, and this was shortly after the combustion fan was running then shut off, other than that the temps have not gone over 185, the 6006 is set at 170. so should I even worry about getting some type of safety zone in for when I loose power? I am just worried about my pex failing, I think that could see temps of 210 without much worry, remind you my zones are completely open and are thermosyphoning which is why I have been staying pretty even with my temps I think.

 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Sun. Oct. 04, 2015 11:32 am

Feeling froggy? Rev her up good and then dump the circuit breaker and stand back to see what unfolds. :|

 
User avatar
hotblast1357
Member
Posts: 5657
Joined: Mon. Mar. 10, 2014 10:06 pm
Location: Peasleeville NY
Stoker Coal Boiler: 1984 Eshland S260 coal gun
Coal Size/Type: Lehigh anthracite pea
Other Heating: air source heat pump, oil furnace

Post by hotblast1357 » Sun. Oct. 04, 2015 1:51 pm

I think I will when I get a couple hours and get a fresh full load in, but of coarse when it gets COLD the thermosyphoning will change too won't it. The duct work will pull harder.


 
alpineboard
Member
Posts: 302
Joined: Thu. Jan. 20, 2011 8:12 am
Stoker Coal Boiler: Van Wert 600
Hand Fed Coal Boiler: Tarm 202
Hand Fed Coal Stove: Harman HXL, 150, Crane 88, Crane 404
Other Heating: Solar

Post by alpineboard » Thu. Oct. 08, 2015 6:43 pm

About zone valves, they are prone to getting stuck when not used much. I suppose water conditions plays a big part in this.

 
User avatar
SMITTY
Member
Posts: 12520
Joined: Sun. Dec. 11, 2005 12:43 pm
Location: West-Central Mass
Stoker Coal Boiler: EFM 520 Highboy
Coal Size/Type: Rice / Blaschak anthracite
Other Heating: Oil fired Burnham boiler

Post by SMITTY » Thu. Oct. 08, 2015 6:47 pm

Burning2nd wrote:Image

This is what I intend on puting on my keystoker... .....
I have that exact unit running my computer and a few other things. It's been through a few outages & performed pretty well. Good enough to get my computer stuff finished, so I can shut it down properly, and go out and hook the gen up.

I'd probably want at least double this unit's size for stoker duty, however. The longer it can run without anyone around, the better.

Drawing just 72 Watts, it only gives me about a half hour, if that .. even though the display says it's good for an hour or more.

 
User avatar
hotblast1357
Member
Posts: 5657
Joined: Mon. Mar. 10, 2014 10:06 pm
Location: Peasleeville NY
Stoker Coal Boiler: 1984 Eshland S260 coal gun
Coal Size/Type: Lehigh anthracite pea
Other Heating: air source heat pump, oil furnace

Post by hotblast1357 » Thu. Oct. 08, 2015 8:21 pm

alright, so the zone valve will possibly be stuck closed because it will rarely get used, am I better off too mount a radiator somewhere and hook up a taco 007 to a UPS and when the power fails just run that pump keeping the boiler from over heating?

 
User avatar
hotblast1357
Member
Posts: 5657
Joined: Mon. Mar. 10, 2014 10:06 pm
Location: Peasleeville NY
Stoker Coal Boiler: 1984 Eshland S260 coal gun
Coal Size/Type: Lehigh anthracite pea
Other Heating: air source heat pump, oil furnace

Post by hotblast1357 » Sat. Nov. 14, 2015 8:18 am

alright so for those following, I plumbed in the gravity dump zone for no electricity and it does not work, refer to this thread for the info.

Power Outage Safety Zone, Hand Fed Boiler

so im back to this, a UPS set up so that it will keep things under control, I just need to power my pump at .75 amps, and modine at 1.3 amps. while watching my boiler dump, it only runs the dump zone for about a minute, maybe minute and a half. the modine is a great dump zone and pulls the water temp down fast. so I would say that a two hour run time would be the most needed, thats for if im away from home for say 16 hours or so.

http://www.amazon.com/gp/product/B000QZ3UG0?keywo ... =pc&sr=1-5

would that work? I just have to get a couple deep cycle agm batteries?

Post Reply